Changes for page 3.4 Protections
Last modified by Admin on 2025/11/06 10:39
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -160,7 +160,7 @@ 160 160 161 161 Conditions for removing the error: 162 162 163 -* the minimumtemperatureamongallcellsofthebatteryisgreaterthan the “Tolerant charging(discharging) temperature” value for the “Delay before clearing the error” time.163 +* the voltage difference between the most charged cell and the least charged cell is less than the “Tolerant cell imbalance” value for the “Delay before clearing the error” time. 164 164 165 165 === Low temperature === 166 166 ... ... @@ -433,7 +433,7 @@ 433 433 434 434 To change the protection parameters from the mismatch of the number of BMS Logic devices to the set value, select the "Protections → Logic count” section: 435 435 436 -[[image:17 33328415732-163.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="110" width="800"]]436 +[[image:1762425434368-516.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]] 437 437 438 438 In this section: 439 439 ... ... @@ -440,6 +440,8 @@ 440 440 * Enable – a flag to enable the protection; 441 441 * Logic count – a number of BMS Logic devices connected to the BMS Main; 442 442 * Scan fast – a flag to scan BMS Logic devices fast (devices with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time); 443 +* Delay before setting the error – a delay before setting the error //during initialization//, millisecond; 444 +* Delay before clearing the error– a delay before clearing the error //during initialization//, second; 443 443 * Lock – lock the error until the device is reset. 444 444 445 445 As a result of the operation of the protection from the mismatch of the number of BMS Logic devices, the "Logic count error" is generated. ... ... @@ -446,11 +446,13 @@ 446 446 447 447 Error generation conditions: 448 448 449 -* the number of BMS Logic devices connected to the BMS Main is **not equal** to the “Logic count” value. 451 +* during the initialization BMS Main 3 have not found required number of BMS Logic devices during the "Delay before setting the error" time; 452 +* after the initialization the number of BMS Logic devices connected to the BMS Main is **not equal** to the “Logic count” value. 450 450 451 451 Conditions for removing the error: 452 452 453 -* the number of BMS Logic devices connected to the BMS Main is **equal** to the “Logic count” value. 456 +* during the initialization BMS Main 3 have found required number of BMS Logic devices and the "Delay before setting the error" time has passed; 457 +* after the initialization the number of BMS Logic devices connected to the BMS Main is **equal** to the “Logic count” value. 454 454 455 455 (% class="box warningmessage" %) 456 456 (((
- 1762425390154-843.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.8 KB - Content
- 1762425434368-516.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.8 KB - Content