... ... @@ -152,15 +152,15 @@
152 152  * Delay before clearing the error, second;
153 153  * Lock – a flag to block the error until the device is restarted.
154 154  
155 -As a result of the operation of the battery protection from cell imbalance, the "Cell im” error are generated.
155 +As a result of the operation of the battery protection from cell imbalance, the "Cell imbalance” error is generated.
156 156  
157 157  Error generation conditions:
158 158  
159 -* the minimum temperature among all cells of the battery is less than the “Minimum charging (discharging) temperature” value for the “Delay before setting the error” time.
159 +* the voltage difference between the most charged cell and the least charged cell is more than the “Maximum cell imbalance” value for the “Delay before setting the error” time.
160 160  
161 161  Conditions for removing the error:
162 162  
163 -* the minimum temperature among all cells of the battery is greater than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time.
163 +* the voltage difference between the most charged cell and the least charged cell is less than the “Tolerant cell imbalance” value for the “Delay before clearing the error” time.
164 164  
165 165  === Low temperature ===
166 166