... ... @@ -137,31 +137,6 @@
137 137  
138 138  * the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time.
139 139  
140 -=== Cell imbalance ===
141 -
142 -The BMS Main 3 device implements battery protection from too much cell imbalance. If balancing algorithm is not enough to compensate battery imbalance, then imbalance protection generates an error when imbalance is above estimated threshold.
143 -
144 -To change the battery protection parameters from cell imbalance, select the "Protections → Cell imbalance" section:
145 -
146 -[[image:1760437465709-702.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="133" width="800"]]In this section:
147 -
148 -* Enable – a flag to enable the protection;
149 -* Maximum cell imbalance, V;
150 -* Tolerant cell imbalance, V;
151 -* Delay before setting the error, millisecond;
152 -* Delay before clearing the error, second;
153 -* Lock – a flag to block the error until the device is restarted.
154 -
155 -As a result of the operation of the battery protection from cell imbalance, the "Cell im” error are generated.
156 -
157 -Error generation conditions:
158 -
159 -* the minimum temperature among all cells of the battery is less than the “Minimum charging (discharging) temperature” value for the “Delay before setting the error” time.
160 -
161 -Conditions for removing the error:
162 -
163 -* the minimum temperature among all cells of the battery is greater than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time.
164 -
165 165  === Low temperature ===
166 166  
167 167  The BMS Main 3 device implements battery protection from too low temperature.
... ... @@ -414,19 +414,19 @@
414 414  * Delay before clearing the error, second;
415 415  * Lock – a flag to block the error until the device is restarted.
416 416  
417 -As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensor count error" is generated.
392 +As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensocount error" is generated.
418 418  
419 419  Error generation conditions:
420 420  
421 -* the number of temperature sensors connected to the BMS is **not equal** to the “Number of temperature sensors” value during the “Delay before setting the error” time.
396 +* the number of cells connected to the BMS is **not equal** to the “Number of cells” value during the “Delay before setting the error” time.
422 422  
423 423  Conditions for removing the error:
424 424  
425 -* the number of temperature sensors connected to the BMS is **equal** to the “Number of temperature sensors” value during the “Delay before clearing the error” time.
400 +* the number of cells connected to the BMS is **equal** to the “Number of cells” value during the “Delay before clearing the error” time.
426 426  
427 427  (% class="box warningmessage" %)
428 428  (((
429 -If there is the "T-sensor count error", the **“Critical error” **is generated**.**
404 +If there is the "Cell count error", the **“Critical error” **is generated**.**
430 430  )))
431 431  
432 432  === Logic count ===
... ... @@ -820,37 +820,6 @@
820 820  If there is the “HVIL error”, the **“Critical error”** is generated.
821 821  )))
822 822  
823 -=== Battery voltage ===
824 -
825 -The BMS Main 3 allows to control the difference between sum of all cell voltages and voltage measured before the contactors.
826 -
827 -To change the voltage difference check parameters, select the "Protections → Battery voltage" section:
828 -
829 -[[image:1755871661259-633.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]]
830 -
831 -In this section:
832 -
833 -* Enable – a flag to enable the protection;
834 -* Abnormal voltage difference – a maximum difference between sum of all cell voltages and voltage measured before the contactors (High voltage 1), V;
835 -* Delay before setting the error, second;
836 -* Delay before clearing the error, second;
837 -* Lock – a flag to block the error until the device is restarted.
838 -
839 -If there is a mismatch between voltages, "Battery voltage mismatch" error is generated.
840 -
841 -Error generation conditions:
842 -
843 -* difference between sum of all cell voltages and voltage measured before the contactors is **more **than "Abnormal voltage difference" value during "Delay before setting the error" time.
844 -
845 -Conditions for removing the error:
846 -
847 -* difference between sum of all cell voltages and voltage measured before the contactors is **less **than "Abnormal voltage difference" value during "Delay before clearing the error" time.
848 -
849 -(% class="box warningmessage" %)
850 -(((
851 -If there is the “Battery voltage mismatch” error, the **“Critical error”** is generated.
852 -)))
853 -
854 854  === Critical error ===
855 855  
856 856  Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault.
1760434646517-885.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -21.4 KB
Content
1760436309214-414.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -19.4 KB
Content
1760437465709-702.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -19.4 KB
Content