Changes for page 3.4 Protections
Last modified by Admin on 2025/11/06 10:39
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -143,28 +143,24 @@ 143 143 144 144 To change the battery protection parameters from cell imbalance, select the "Protections → Cell imbalance" section: 145 145 146 -[[image:1760437465709-702.png]] 146 +[[image:1760437465709-702.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="133" width="800"]]In this section: 147 147 148 -In this section: 149 - 150 150 * Enable – a flag to enable the protection; 151 -* Minimum charge temperature, °C; 152 -* Tolerant charge temperature, °C; 153 -* Minimum discharge temperature, °C; 154 -* Tolerant discharge temperature, °C; 149 +* Maximum cell imbalance, V; 150 +* Tolerant cell imbalance, V; 155 155 * Delay before setting the error, millisecond; 156 156 * Delay before clearing the error, second; 157 157 * Lock – a flag to block the error until the device is restarted. 158 158 159 -As a result of the operation of the battery protection from l owtemperature, the "Low temperature (CH)"and/or “Low temperature (DCH)” erroraregenerated.155 +As a result of the operation of the battery protection from cell imbalance, the "Cell imbalance” error is generated. 160 160 161 161 Error generation conditions: 162 162 163 -* the minimumtemperatureamongallcellsofthebatteryislessthan the “Minimum charging(discharging) temperature” value for the “Delay before setting the error” time.159 +* the voltage difference between the most charged cell and the least charged cell is more than the “Maximum cell imbalance” value for the “Delay before setting the error” time. 164 164 165 165 Conditions for removing the error: 166 166 167 -* the minimumtemperatureamongallcellsofthebatteryisgreaterthan the “Tolerant charging(discharging) temperature” value for the “Delay before clearing the error” time.163 +* the voltage difference between the most charged cell and the least charged cell is less than the “Tolerant cell imbalance” value for the “Delay before clearing the error” time. 168 168 169 169 === Low temperature === 170 170 ... ... @@ -437,7 +437,7 @@ 437 437 438 438 To change the protection parameters from the mismatch of the number of BMS Logic devices to the set value, select the "Protections → Logic count” section: 439 439 440 -[[image:17 33328415732-163.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="110" width="800"]]436 +[[image:1762425434368-516.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]] 441 441 442 442 In this section: 443 443 ... ... @@ -444,6 +444,8 @@ 444 444 * Enable – a flag to enable the protection; 445 445 * Logic count – a number of BMS Logic devices connected to the BMS Main; 446 446 * Scan fast – a flag to scan BMS Logic devices fast (devices with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time); 443 +* Delay before setting the error – a delay before setting the error //during initialization//, millisecond; 444 +* Delay before clearing the error– a delay before clearing the error //during initialization//, second; 447 447 * Lock – lock the error until the device is reset. 448 448 449 449 As a result of the operation of the protection from the mismatch of the number of BMS Logic devices, the "Logic count error" is generated. ... ... @@ -450,11 +450,13 @@ 450 450 451 451 Error generation conditions: 452 452 453 -* the number of BMS Logic devices connected to the BMS Main is **not equal** to the “Logic count” value. 451 +* during the initialization BMS Main 3 have not found required number of BMS Logic devices during the "Delay before setting the error" time; 452 +* after the initialization the number of BMS Logic devices connected to the BMS Main is **not equal** to the “Logic count” value. 454 454 455 455 Conditions for removing the error: 456 456 457 -* the number of BMS Logic devices connected to the BMS Main is **equal** to the “Logic count” value. 456 +* during the initialization BMS Main 3 have found required number of BMS Logic devices and the "Delay before setting the error" time has passed; 457 +* after the initialization the number of BMS Logic devices connected to the BMS Main is **equal** to the “Logic count” value. 458 458 459 459 (% class="box warningmessage" %) 460 460 (((
- 1762425390154-843.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.8 KB - Content
- 1762425434368-516.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.8 KB - Content