143 143  
144 144  To change the battery protection parameters from cell imbalance, select the "Protections → Cell imbalance" section:
145 145  
146 -[[image:1760437465709-702.png]]
146 +[[image:1760437465709-702.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="133" width="800"]]In this section:
147 147  
148 -In this section:
149 -
150 150  * Enable – a flag to enable the protection;
151 -* Minimum charge temperature, °C;
152 -* Tolerant charge temperature, °C;
153 -* Minimum discharge temperature, °C;
154 -* Tolerant discharge temperature, °C;
149 +* Maximum cell imbalance, V;
150 +* Tolerant cell imbalance, V;
155 155  * Delay before setting the error, millisecond;
156 156  * Delay before clearing the error, second;
157 157  * Lock – a flag to block the error until the device is restarted.
158 158  
159 -As a result of the operation of the battery protection from low temperature, the "Low temperature (CH)" and/or “Low temperature (DCH)” error are generated.
155 +As a result of the operation of the battery protection from cell imbalance, the "Cell imbalance” error is generated.
160 160  
161 161  Error generation conditions:
162 162  
163 -* the minimum temperature among all cells of the battery is less than the “Minimum charging (discharging) temperature” value for the “Delay before setting the error” time.
159 +* the voltage difference between the most charged cell and the least charged cell is more than the “Maximum cell imbalance” value for the “Delay before setting the error” time.
164 164  
165 165  Conditions for removing the error:
166 166