Changes for page 3.4 Protections
Last modified by Admin on 2025/10/14 10:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -137,35 +137,6 @@ 137 137 138 138 * the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 139 139 140 -=== Cell imbalance === 141 - 142 -The BMS Main 3 device implements battery protection from too much cell imbalance. If balancing algorithm is not enough to compensate battery imbalance, then imbalance protection generates an error when imbalance is above estimated threshold. 143 - 144 -To change the battery protection parameters from cell imbalance, select the "Protections → Cell imbalance" section: 145 - 146 -[[image:1760437465709-702.png]] 147 - 148 -In this section: 149 - 150 -* Enable – a flag to enable the protection; 151 -* Minimum charge temperature, °C; 152 -* Tolerant charge temperature, °C; 153 -* Minimum discharge temperature, °C; 154 -* Tolerant discharge temperature, °C; 155 -* Delay before setting the error, millisecond; 156 -* Delay before clearing the error, second; 157 -* Lock – a flag to block the error until the device is restarted. 158 - 159 -As a result of the operation of the battery protection from low temperature, the "Low temperature (CH)" and/or “Low temperature (DCH)” error are generated. 160 - 161 -Error generation conditions: 162 - 163 -* the minimum temperature among all cells of the battery is less than the “Minimum charging (discharging) temperature” value for the “Delay before setting the error” time. 164 - 165 -Conditions for removing the error: 166 - 167 -* the minimum temperature among all cells of the battery is greater than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 168 - 169 169 === Low temperature === 170 170 171 171 The BMS Main 3 device implements battery protection from too low temperature. ... ... @@ -418,19 +418,19 @@ 418 418 * Delay before clearing the error, second; 419 419 * Lock – a flag to block the error until the device is restarted. 420 420 421 -As a result of the operation of the protection from the mismatch of the number of cells, the "T-senso rcount error" is generated.392 +As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensocount error" is generated. 422 422 423 423 Error generation conditions: 424 424 425 -* the number of temperaturesensorsconnected to the BMS is **not equal** to the “Number oftemperaturesensors” value during the “Delay before setting the error” time.396 +* the number of cells connected to the BMS is **not equal** to the “Number of cells” value during the “Delay before setting the error” time. 426 426 427 427 Conditions for removing the error: 428 428 429 -* the number of temperaturesensorsconnected to the BMS is **equal** to the “Number oftemperaturesensors” value during the “Delay before clearing the error” time.400 +* the number of cells connected to the BMS is **equal** to the “Number of cells” value during the “Delay before clearing the error” time. 430 430 431 431 (% class="box warningmessage" %) 432 432 ((( 433 -If there is the " T-sensorcount error", the **“Critical error” **is generated**.**404 +If there is the "Cell count error", the **“Critical error” **is generated**.** 434 434 ))) 435 435 436 436 === Logic count === ... ... @@ -824,37 +824,6 @@ 824 824 If there is the “HVIL error”, the **“Critical error”** is generated. 825 825 ))) 826 826 827 -=== Battery voltage === 828 - 829 -The BMS Main 3 allows to control the difference between sum of all cell voltages and voltage measured before the contactors. 830 - 831 -To change the voltage difference check parameters, select the "Protections → Battery voltage" section: 832 - 833 -[[image:1755871661259-633.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]] 834 - 835 -In this section: 836 - 837 -* Enable – a flag to enable the protection; 838 -* Abnormal voltage difference – a maximum difference between sum of all cell voltages and voltage measured before the contactors (High voltage 1), V; 839 -* Delay before setting the error, second; 840 -* Delay before clearing the error, second; 841 -* Lock – a flag to block the error until the device is restarted. 842 - 843 -If there is a mismatch between voltages, "Battery voltage mismatch" error is generated. 844 - 845 -Error generation conditions: 846 - 847 -* difference between sum of all cell voltages and voltage measured before the contactors is **more **than "Abnormal voltage difference" value during "Delay before setting the error" time. 848 - 849 -Conditions for removing the error: 850 - 851 -* difference between sum of all cell voltages and voltage measured before the contactors is **less **than "Abnormal voltage difference" value during "Delay before clearing the error" time. 852 - 853 -(% class="box warningmessage" %) 854 -((( 855 -If there is the “Battery voltage mismatch” error, the **“Critical error”** is generated. 856 -))) 857 - 858 858 === Critical error === 859 859 860 860 Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault.
- 1760434646517-885.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -21.4 KB - Content
- 1760436309214-414.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.4 KB - Content
- 1760437465709-702.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.4 KB - Content