Changes for page 3.4 Protections
Last modified by Admin on 2025/10/14 10:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -137,12 +137,6 @@ 137 137 138 138 * the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 139 139 140 -=== Cell imbalance === 141 - 142 -The BMS Main 3 device implements battery protection from too much cell imbalance. If balancing algorithm is not enough to compensate battery imbalance, then imbalance protection generates an error 143 - 144 -To change the battery protection parameters from low temperature, select the "Protections → Low temperature" section: 145 - 146 146 === Low temperature === 147 147 148 148 The BMS Main 3 device implements battery protection from too low temperature. ... ... @@ -395,19 +395,19 @@ 395 395 * Delay before clearing the error, second; 396 396 * Lock – a flag to block the error until the device is restarted. 397 397 398 -As a result of the operation of the protection from the mismatch of the number of cells, the "T-senso rcount error" is generated.392 +As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensocount error" is generated. 399 399 400 400 Error generation conditions: 401 401 402 -* the number of temperaturesensorsconnected to the BMS is **not equal** to the “Number oftemperaturesensors” value during the “Delay before setting the error” time.396 +* the number of cells connected to the BMS is **not equal** to the “Number of cells” value during the “Delay before setting the error” time. 403 403 404 404 Conditions for removing the error: 405 405 406 -* the number of temperaturesensorsconnected to the BMS is **equal** to the “Number oftemperaturesensors” value during the “Delay before clearing the error” time.400 +* the number of cells connected to the BMS is **equal** to the “Number of cells” value during the “Delay before clearing the error” time. 407 407 408 408 (% class="box warningmessage" %) 409 409 ((( 410 -If there is the " T-sensorcount error", the **“Critical error” **is generated**.**404 +If there is the "Cell count error", the **“Critical error” **is generated**.** 411 411 ))) 412 412 413 413 === Logic count === ... ... @@ -801,37 +801,6 @@ 801 801 If there is the “HVIL error”, the **“Critical error”** is generated. 802 802 ))) 803 803 804 -=== Battery voltage === 805 - 806 -The BMS Main 3 allows to control the difference between sum of all cell voltages and voltage measured before the contactors. 807 - 808 -To change the voltage difference check parameters, select the "Protections → Battery voltage" section: 809 - 810 -[[image:1755871661259-633.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]] 811 - 812 -In this section: 813 - 814 -* Enable – a flag to enable the protection; 815 -* Abnormal voltage difference – a maximum difference between sum of all cell voltages and voltage measured before the contactors (High voltage 1), V; 816 -* Delay before setting the error, second; 817 -* Delay before clearing the error, second; 818 -* Lock – a flag to block the error until the device is restarted. 819 - 820 -If there is a mismatch between voltages, "Battery voltage mismatch" error is generated. 821 - 822 -Error generation conditions: 823 - 824 -* difference between sum of all cell voltages and voltage measured before the contactors is **more **than "Abnormal voltage difference" value during "Delay before setting the error" time. 825 - 826 -Conditions for removing the error: 827 - 828 -* difference between sum of all cell voltages and voltage measured before the contactors is **less **than "Abnormal voltage difference" value during "Delay before clearing the error" time. 829 - 830 -(% class="box warningmessage" %) 831 -((( 832 -If there is the “Battery voltage mismatch” error, the **“Critical error”** is generated. 833 -))) 834 - 835 835 === Critical error === 836 836 837 837 Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault.
- 1760434646517-885.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -21.4 KB - Content
- 1760436309214-414.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.4 KB - Content
- 1760437465709-702.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.4 KB - Content