Changes for page 3.4 Protections
Last modified by Admin on 2025/10/14 10:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 8 removed)
Details
- Page properties
-
- Content
-
... ... @@ -94,7 +94,7 @@ 94 94 * Enable – a flag to enable the protection; 95 95 * Minimum cell voltage, V; 96 96 * Tolerant cell voltage, V; 97 -* Check the open circuit voltage instead of the actual voltage – a flag to use theU,,ocv,, (correcteddue to current and cell resistance) cell voltage;97 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 98 98 * Delay before setting the error, millisecond; 99 99 * Delay before clearing the error, second; 100 100 * Lock – a flag to block the error until the device is restarted. ... ... @@ -122,7 +122,7 @@ 122 122 * Enable – a flag to enable the protection; 123 123 * Maximum cell voltage, V; 124 124 * Tolerant cell voltage, V; 125 -* Check the open circuit voltage instead of the actual voltage – a flag to use theU,,ocv,, (correcteddue to current and cell resistance) cell voltage;125 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 126 126 * Delay before setting the error, millisecond; 127 127 * Delay before clearing the error, second; 128 128 * Lock – a flag to block the error until the device is restarted. ... ... @@ -137,12 +137,6 @@ 137 137 138 138 * the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 139 139 140 -=== Cell imbalance === 141 - 142 -The BMS Main 3 device implements battery protection from too much cell imbalance. If balancing algorithm is not enough to compensate 143 - 144 -To change the battery protection parameters from low temperature, select the "Protections → Low temperature" section: 145 - 146 146 === Low temperature === 147 147 148 148 The BMS Main 3 device implements battery protection from too low temperature. ... ... @@ -327,14 +327,11 @@ 327 327 328 328 To change the protection parameters from loss of communication with BMS Logic devices, select the "Protections → Logic offline" section: 329 329 330 -[[image:17 55871522789-489.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]324 +[[image:1733328399416-818.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="86" width="800"]] 331 331 332 - 333 333 In this section: 334 334 335 335 * Enable – a flag to enable the protection; 336 -* Delay before setting the error, second; 337 -* Delay before clearing the error, second; 338 338 * Lock – lock the error until the device is reset. 339 339 340 340 As a result of the protection from loss of communication with BMS Logic devices, the "Logic offline" error is generated. ... ... @@ -381,35 +381,6 @@ 381 381 If there is the "Cell count error", the **“Critical error” **is generated**.** 382 382 ))) 383 383 384 -=== Temperature sensor count === 385 - 386 -To change the protection parameters from the mismatch of the number of temperature sensors to the set value, select the "Protections → Temperature sensor count" section: 387 - 388 -[[image:1755871582533-550.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 389 - 390 -In this section: 391 - 392 -* Enable – a flag to enable the protection; 393 -* Number of cells – a number of temperature sensors connected to the BMS; 394 -* Delay before setting the error, millisecond; 395 -* Delay before clearing the error, second; 396 -* Lock – a flag to block the error until the device is restarted. 397 - 398 -As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensor count error" is generated. 399 - 400 -Error generation conditions: 401 - 402 -* the number of temperature sensors connected to the BMS is **not equal** to the “Number of temperature sensors” value during the “Delay before setting the error” time. 403 - 404 -Conditions for removing the error: 405 - 406 -* the number of temperature sensors connected to the BMS is **equal** to the “Number of temperature sensors” value during the “Delay before clearing the error” time. 407 - 408 -(% class="box warningmessage" %) 409 -((( 410 -If there is the "T-sensor count error", the **“Critical error” **is generated**.** 411 -))) 412 - 413 413 === Logic count === 414 414 415 415 To change the protection parameters from the mismatch of the number of BMS Logic devices to the set value, select the "Protections → Logic count” section: ... ... @@ -801,37 +801,6 @@ 801 801 If there is the “HVIL error”, the **“Critical error”** is generated. 802 802 ))) 803 803 804 -=== Battery voltage === 805 - 806 -The BMS Main 3 allows to control the difference between sum of all cell voltages and voltage measured before the contactors. 807 - 808 -To change the voltage difference check parameters, select the "Protections → Battery voltage" section: 809 - 810 -[[image:1755871661259-633.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]] 811 - 812 -In this section: 813 - 814 -* Enable – a flag to enable the protection; 815 -* Abnormal voltage difference – a maximum difference between sum of all cell voltages and voltage measured before the contactors (High voltage 1), V; 816 -* Delay before setting the error, second; 817 -* Delay before clearing the error, second; 818 -* Lock – a flag to block the error until the device is restarted. 819 - 820 -If there is a mismatch between voltages, "Battery voltage mismatch" error is generated. 821 - 822 -Error generation conditions: 823 - 824 -* difference between sum of all cell voltages and voltage measured before the contactors is **more **than "Abnormal voltage difference" value during "Delay before setting the error" time. 825 - 826 -Conditions for removing the error: 827 - 828 -* difference between sum of all cell voltages and voltage measured before the contactors is **less **than "Abnormal voltage difference" value during "Delay before clearing the error" time. 829 - 830 -(% class="box warningmessage" %) 831 -((( 832 -If there is the “Battery voltage mismatch” error, the **“Critical error”** is generated. 833 -))) 834 - 835 835 === Critical error === 836 836 837 837 Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault.
- 1755870412909-992.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.5 KB - Content
- 1755870732669-803.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.2 KB - Content
- 1755871195329-366.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -16.0 KB - Content
- 1755871522789-489.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -16.0 KB - Content
- 1755871582533-550.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.2 KB - Content
- 1755871661259-633.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.5 KB - Content
- 1760434646517-885.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -21.4 KB - Content
- 1760436309214-414.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.4 KB - Content