Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.bms-main-3.3\.Settings.WebHome1 +Battery management systems.BMS Main 3.3\. Configuration.WebHome - Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Settings=2 += Configuration = 3 3 4 4 (% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == Protections == ... ... @@ -42,6 +42,14 @@ 42 42 If there is the "Overcurrent" error, the **charging **and **discharging **contactors open. 43 43 ))) 44 44 45 +=== Charge current limit === 46 + 47 +TBA 48 + 49 +=== Discharge current limit === 50 + 51 +TBA 52 + 45 45 === Undervoltage === 46 46 47 47 The BMS Main 3 device implements battery protection from too low voltage on the cells. ... ... @@ -48,7 +48,7 @@ 48 48 49 49 To change the battery protection parameters from low voltage on the cells, select the "Protections → Undervoltage" section: 50 50 51 -[[image:173 3328382380-760.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]]59 +[[image:1735224224155-829.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]] 52 52 53 53 In this section: 54 54 ... ... @@ -55,6 +55,7 @@ 55 55 * Enable – a flag to enable the protection; 56 56 * Minimum cell voltage, V; 57 57 * Tolerant cell voltage, V; 66 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 58 58 * Delay before setting the error, millisecond; 59 59 * Delay before clearing the error, second; 60 60 * Lock – a flag to block the error until the device is restarted. ... ... @@ -87,6 +87,7 @@ 87 87 * Enable – a flag to enable the protection; 88 88 * Maximum cell voltage, V; 89 89 * Tolerant cell voltage, V; 99 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 90 90 * Delay before setting the error, millisecond; 91 91 * Delay before clearing the error, second; 92 92 * Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated; ... ... @@ -269,7 +269,7 @@ 269 269 If there is the “Water” error, the **“Critical error”** is generated and **all relays open**. 270 270 ))) 271 271 272 -=== HighLogic temperature ===282 +=== Logic high temperature === 273 273 274 274 To change the overheating protection parameters of BMS Logic devices, select the "Protections → High Logic temperature" section: 275 275 ... ... @@ -503,6 +503,10 @@ 503 503 If there is the "Power switch error", the **“Critical error” **is generated and **all relays open.** 504 504 ))) 505 505 516 +=== Power fault === 517 + 518 +TBA 519 + 506 506 === Charge contactor cycles === 507 507 508 508 The BMS Main 3 device protects the charging contactor against frequent switching. ... ... @@ -642,7 +642,7 @@ 642 642 If there is the "Unallowable charging" error, the **discharging **contactor opens. 643 643 ))) 644 644 645 -=== Stuck contactor ===659 +=== Stuck contactor === 646 646 647 647 The BMS Main 3 device protects contactors against sticking. 648 648 ... ... @@ -692,30 +692,8 @@ 692 692 If there is the “Contactor feedback” error, the **“Critical error” **is generated and **all relays open.** 693 693 ))) 694 694 695 -=== Precharge===709 +=== Insulation === 696 696 697 -BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors. To change the pre-charge monitoring parameters, select the "Protections → Precharge" section: 698 - 699 -[[image:1733328487097-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="99" width="800"]] 700 - 701 -In this section: 702 - 703 -* Enable – a flag to enable the protection; 704 -* Delay before setting the error, millisecond; 705 -* Delay before clearing the error, second; 706 -* Lock – a flag to block the error until the device is restarted. 707 - 708 -As a result of the protection algorithms the “Precharge error” is generated. Error generation conditions: 709 - 710 -* precharging process cannot be finished (the precharge current does not decrease or voltages before and after contactors are not equal) during the “Delay before setting the error” time. 711 - 712 -(% class="box infomessage" %) 713 -((( 714 -If there is the “Precharge error”, **charging **and **discharging **contactors open. 715 -))) 716 - 717 -=== Insulation === 718 - 719 719 The BMS Main 3 device can detect a physical signal or CAN bus message from an external insulation monitoring device (such as Bender IR155, iso165C, BMD IMD) to monitor the insulation quality. 720 720 721 721 To change the insulation monitoring parameters, select the "Protections → Insulation" section: ... ... @@ -805,7 +805,7 @@ 805 805 If there is the “Critical error”, **all **contactors open. 806 806 ))) 807 807 808 -=== General error ===800 +=== General error === 809 809 810 810 To change the general error parameters, select the "Protections → Critical error" section: 811 811
- 1735224224155-829.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content