Changes for page 3.4 Protections
Last modified by Admin on 2025/08/22 14:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -389,19 +389,19 @@ 389 389 * Delay before clearing the error, second; 390 390 * Lock – a flag to block the error until the device is restarted. 391 391 392 -As a result of the operation of the protection from the mismatch of the number of cells, the "T-senso rcount error" is generated.392 +As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensocount error" is generated. 393 393 394 394 Error generation conditions: 395 395 396 -* the number of temperaturesensorsconnected to the BMS is **not equal** to the “Number oftemperaturesensors” value during the “Delay before setting the error” time.396 +* the number of cells connected to the BMS is **not equal** to the “Number of cells” value during the “Delay before setting the error” time. 397 397 398 398 Conditions for removing the error: 399 399 400 -* the number of temperaturesensorsconnected to the BMS is **equal** to the “Number oftemperaturesensors” value during the “Delay before clearing the error” time.400 +* the number of cells connected to the BMS is **equal** to the “Number of cells” value during the “Delay before clearing the error” time. 401 401 402 402 (% class="box warningmessage" %) 403 403 ((( 404 -If there is the " T-sensorcount error", the **“Critical error” **is generated**.**404 +If there is the "Cell count error", the **“Critical error” **is generated**.** 405 405 ))) 406 406 407 407 === Logic count === ... ... @@ -795,32 +795,6 @@ 795 795 If there is the “HVIL error”, the **“Critical error”** is generated. 796 796 ))) 797 797 798 -=== Battery voltage === 799 - 800 -The BMS Main 3 allows to control the difference between sum of all cell voltages and voltage measured before the contactors. 801 - 802 -To change the HVIL measurement parameters, select the "Protections → Battery voltage" section: 803 - 804 -[[image:1755871661259-633.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]] 805 - 806 -In this section: 807 - 808 -* Enable – a flag to enable the protection; 809 -* Abnormal voltage difference – a maximum difference between sum of all cell voltages and voltage measured before the contactors (High voltage 1), V; 810 -* Delay before setting the error, second; 811 -* Delay before clearing the error, second; 812 -* Lock – a flag to block the error until the device is restarted. 813 - 814 -If there is a mismatch between voltages, "Battery voltage mismatch" error is generated. 815 - 816 -Error generation conditions: 817 - 818 -* difference between sum of all cell voltages and voltage measured before the contactors is **more **than "Abnormal voltage difference" value during "Delay before setting the error" time. 819 - 820 -Conditions for removing the error: 821 - 822 -* difference between sum of all cell voltages and voltage measured before the contactors is **less **than "Abnormal voltage difference" value during "Delay before clearing the error" time. 823 - 824 824 === Critical error === 825 825 826 826 Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault.