Changes for page 3.4 Protections
Last modified by Admin on 2026/04/01 08:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,7 +4,7 @@ 4 4 (% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == Protections == 6 6 7 -The BMS Main 3 device continuously monitors the state of the cells, the external environment and, when detecting abnormalities, protects the battery and system components from damage. 7 +The BMS Main 3 / BMS Main 2R device continuously monitors the state of the cells, the external environment and, when detecting abnormalities, protects the battery and system components from damage. 8 8 9 9 (% class="box errormessage" %) 10 10 ((( ... ... @@ -14,7 +14,7 @@ 14 14 15 15 === Overcurrent === 16 16 17 -The BMS Main 3 device performs the overcurrent protection depending on current sensor values. 17 +The BMS Main 3 / BMS Main 2R device performs the overcurrent protection depending on current sensor values. 18 18 19 19 To change the overcurrent protection of the battery, select the "Protections → Overcurrent" section: 20 20 ... ... @@ -22,14 +22,14 @@ 22 22 23 23 In this section: 24 24 25 -* Enable – a flag to enable the protection; 26 -* Maximum charging current, А; 27 -* Tolerant charging current, А; 28 -* Maximum discharging current, А; 29 -* Tolerant discharging current, А; 30 -* Delay before setting the error, millisecond; 31 -* Delay before clearing the error, second; 32 -* Lock – a flag to block the error until the device is restarted. 25 +* **Enable **– a flag to enable the protection; 26 +* **Maximum charging current**, А; 27 +* **Tolerant charging current**, А; 28 +* **Maximum discharging current**, А; 29 +* **Tolerant discharging current**, А; 30 +* **Delay before setting the error**, millisecond; 31 +* **Delay before clearing the error**, second; 32 +* **Lock **– a flag to block the error until the device is restarted. 33 33 34 34 As a result of operation of the overcurrent protection, the "Overcurrent" error is generated. 35 35 ... ... @@ -45,7 +45,7 @@ 45 45 46 46 === Charge current limit === 47 47 48 -The BMS Main 3 device can check if the charging current exceeds the estimated limit based on the [[Charge map>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HChargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. 48 +The BMS Main 3 / BMS Main 2R device can check if the charging current exceeds the estimated limit based on the [[Charge map>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HChargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. 49 49 50 50 Current difference is separated to two regions by the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference. 51 51 ... ... @@ -53,17 +53,17 @@ 53 53 54 54 [[image:1735225207687-430.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="800"]]In this section: 55 55 56 -* Enable – a flag to enable the protection; 57 -* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 58 -* Region 1: Current difference – a value of maximum absolute current difference, A; 59 -* Region 2: Current difference – a value of maximum relative current excess, A; 60 -* Delay before setting the error, millisecond; 61 -* Delay before clearing the error, second; 62 -* Lock – a flag to block the error until the device is restarted. 56 +* **Enable **– a flag to enable the protection; 57 +* **Threshold to switch from Region 1 to Region 2** – a current value at which current excess calculation will be switched from absolute to relative difference, A; 58 +* **Region 1: Current difference** – a value of maximum absolute current difference, A; 59 +* **Region 2: Current difference** – a value of maximum relative current excess, A; 60 +* **Delay before setting the error**, millisecond; 61 +* **Delay before clearing the error**, second; 62 +* **Lock **– a flag to block the error until the device is restarted. 63 63 64 64 === Discharge current limit === 65 65 66 -The BMS Main 3 device can check if the discharging current exceeds the estimated limit based on the [[Discharge map>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HDischargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. 66 +The BMS Main 3 / BMS Main 2R device can check if the discharging current exceeds the estimated limit based on the [[Discharge map>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HDischargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. 67 67 68 68 Current difference is separated to two regions by the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference. 69 69 ... ... @@ -73,17 +73,17 @@ 73 73 74 74 In this section: 75 75 76 -* Enable – a flag to enable the protection; 77 -* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 78 -* Region 1: Current difference – a value of maximum absolute current difference, A; 79 -* Region 2: Current difference – a value of maximum relative current excess, A; 80 -* Delay before setting the error, millisecond; 81 -* Delay before clearing the error, second; 82 -* Lock – a flag to block the error until the device is restarted. 76 +* **Enable **– a flag to enable the protection; 77 +* **Threshold to switch from Region 1 to Region 2** – a current value at which current excess calculation will be switched from absolute to relative difference, A; 78 +* **Region 1: Current difference** – a value of maximum absolute current difference, A; 79 +* **Region 2: Current difference** – a value of maximum relative current excess, A; 80 +* **Delay before setting the error**, millisecond; 81 +* **Delay before clearing the error**, second; 82 +* **Lock **– a flag to block the error until the device is restarted. 83 83 84 84 === Undervoltage === 85 85 86 -The BMS Main 3 device implements battery protection from too low voltage on the cells. 86 +The BMS Main 3 / BMS Main 2R device implements battery protection from too low voltage on the cells. 87 87 88 88 To change the battery protection parameters from low voltage on the cells, select the "Protections → Undervoltage" section: 89 89 ... ... @@ -91,13 +91,13 @@ 91 91 92 92 In this section: 93 93 94 -* Enable – a flag to enable the protection; 95 -* Minimum cell voltage, V; 96 -* Tolerant cell voltage, V; 97 -* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 98 -* Delay before setting the error, millisecond; 99 -* Delay before clearing the error, second; 100 -* Lock – a flag to block the error until the device is restarted. 94 +* **Enable **– a flag to enable the protection; 95 +* **Minimum cell voltage**, V; 96 +* **Tolerant cell voltage**, V; 97 +* **Check the open circuit voltage instead of the actual voltage** – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 98 +* **Delay before setting the error**, millisecond; 99 +* **Delay before clearing the error**, second; 100 +* **Lock **– a flag to block the error until the device is restarted. 101 101 102 102 As a result of the operation of battery protection from low voltage, the "Undervoltage" error is generated. 103 103 ... ... @@ -111,7 +111,7 @@ 111 111 112 112 === Overvoltage === 113 113 114 -The BMS Main 3 device implements battery protection from too high voltage on the cells. 114 +The BMS Main 3 / BMS Main 2R device implements battery protection from too high voltage on the cells. 115 115 116 116 To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section: 117 117 ... ... @@ -119,13 +119,13 @@ 119 119 120 120 In this section: 121 121 122 -* Enable – a flag to enable the protection; 123 -* Maximum cell voltage, V; 124 -* Tolerant cell voltage, V; 125 -* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 126 -* Delay before setting the error, millisecond; 127 -* Delay before clearing the error, second; 128 -* Lock – a flag to block the error until the device is restarted. 122 +* **Enable **– a flag to enable the protection; 123 +* **Maximum cell voltage**, V; 124 +* **Tolerant cell voltage**, V; 125 +* **Check the open circuit voltage instead of the actual voltage** – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 126 +* **Delay before setting the error**, millisecond; 127 +* **Delay before clearing the error**, second; 128 +* **Lock **– a flag to block the error until the device is restarted. 129 129 130 130 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. 131 131 ... ... @@ -137,9 +137,34 @@ 137 137 138 138 * the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 139 139 140 +=== Cell imbalance === 141 + 142 +The BMS Main 3 / BMS Main 2R device implements battery protection from too much cell imbalance. If balancing algorithm is not enough to compensate battery imbalance, then imbalance protection generates an error when imbalance is above estimated threshold. 143 + 144 +To change the battery protection parameters from cell imbalance, select the "Protections → Cell imbalance" section: 145 + 146 +[[image:1760437465709-702.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="133" width="800"]]In this section: 147 + 148 +* **Enable **– a flag to enable the protection; 149 +* **Maximum cell imbalance**, V; 150 +* **Tolerant cell imbalance**, V; 151 +* **Delay before setting the error**, millisecond; 152 +* **Delay before clearing the error**, second; 153 +* **Lock **– a flag to block the error until the device is restarted. 154 + 155 +As a result of the operation of the battery protection from cell imbalance, the "Cell imbalance” error is generated. 156 + 157 +Error generation conditions: 158 + 159 +* the voltage difference between the most charged cell and the least charged cell is more than the “Maximum cell imbalance” value for the “Delay before setting the error” time. 160 + 161 +Conditions for removing the error: 162 + 163 +* the voltage difference between the most charged cell and the least charged cell is less than the “Tolerant cell imbalance” value for the “Delay before clearing the error” time. 164 + 140 140 === Low temperature === 141 141 142 -The BMS Main 3 device implements battery protection from too low temperature. 167 +The BMS Main 3 / BMS Main 2R device implements battery protection from too low temperature. 143 143 144 144 To change the battery protection parameters from low temperature, select the "Protections → Low temperature" section: 145 145 ... ... @@ -147,14 +147,14 @@ 147 147 148 148 In this section: 149 149 150 -* Enable – a flag to enable the protection; 151 -* Minimum charge temperature, °C; 152 -* Tolerant charge temperature, °C; 153 -* Minimum discharge temperature, °C; 154 -* Tolerant discharge temperature, °C; 155 -* Delay before setting the error, millisecond; 156 -* Delay before clearing the error, second; 157 -* Lock – a flag to block the error until the device is restarted. 175 +* **Enable **– a flag to enable the protection; 176 +* **Minimum charge temperature**, °C; 177 +* **Tolerant charge temperature**, °C; 178 +* **Minimum discharge temperature**, °C; 179 +* **Tolerant discharge temperature**, °C; 180 +* **Delay before setting the error**, millisecond; 181 +* **Delay before clearing the error**, second; 182 +* **Lock **– a flag to block the error until the device is restarted. 158 158 159 159 As a result of the operation of the battery protection from low temperature, the "Low temperature (CH)" and/or “Low temperature (DCH)” error are generated. 160 160 ... ... @@ -168,7 +168,7 @@ 168 168 169 169 === High temperature === 170 170 171 -The BMS Main 3 device implements battery protection from too high temperature. 196 +The BMS Main 3 / BMS Main 2R device implements battery protection from too high temperature. 172 172 173 173 To change the battery protection parameters from high temperature, select the "Protections → High temperature" section: 174 174 ... ... @@ -176,14 +176,14 @@ 176 176 177 177 In this section: 178 178 179 -* Enable – a flag to enable the protection; 180 -* Maximum charge temperature, °C; 181 -* Tolerant charge temperature, °C; 182 -* Maximum discharge temperature, °C; 183 -* Tolerant discharge temperature, °C; 184 -* Delay before setting the error, millisecond; 185 -* Delay before clearing the error, second; 186 -* Lock – a flag to block the error until the device is restarted. 204 +* **Enable **– a flag to enable the protection; 205 +* **Maximum charge temperature**, °C; 206 +* **Tolerant charge temperature**, °C; 207 +* **Maximum discharge temperature**, °C; 208 +* **Tolerant discharge temperature**, °C; 209 +* **Delay before setting the error**, millisecond; 210 +* **Delay before clearing the error**, second; 211 +* **Lock **– a flag to block the error until the device is restarted. 187 187 188 188 As a result of the operation of the battery protection from high temperature, the "High temperature (CH)" or “High temperature (DCH)” error is generated. 189 189 ... ... @@ -203,10 +203,10 @@ 203 203 204 204 In this section: 205 205 206 -* Enable – a flag to enable the protection; 207 -* Delay before setting the error, millisecond; 208 -* Delay before clearing the error, second; 209 -* Lock – a flag to block the error until the device is restarted. 231 +* **Enable** – a flag to enable the protection; 232 +* **Delay before setting the error**, millisecond; 233 +* **Delay before clearing the error**, second; 234 +* **Lock **– a flag to block the error until the device is restarted. 210 210 211 211 As a result of the operation of the protection against opening the battery cover, the “Battery cover error” is generated. 212 212 ... ... @@ -225,7 +225,7 @@ 225 225 226 226 === High humidity === 227 227 228 -The BMS Main 3 can detect that the battery is operating in high humidity conditions. 253 +The BMS Main 3 / BMS Main 2R can detect that the battery is operating in high humidity conditions. 229 229 230 230 To change the detection parameters, select the "Protections → High humidity" section: 231 231 ... ... @@ -233,12 +233,12 @@ 233 233 234 234 In this section: 235 235 236 -* Enable – a flag to enable the detection; 237 -* Maximum humidity, RH%; 238 -* Tolerant humidity, RH%; 239 -* Delay before setting the error, second; 240 -* Delay before clearing the error, second; 241 -* Lock the error until the device is res et.261 +* **Enable **– a flag to enable the detection; 262 +* **Maximum humidity**, RH%; 263 +* **Tolerant humidity**, RH%; 264 +* **Delay before setting the error**, second; 265 +* **Delay before clearing the error**, second; 266 +* **Lock **– a flag to block the error until the device is restarted. 242 242 243 243 As a result of the operation of the battery protection from high humidity, the "High humidity" error is generated. 244 244 ... ... @@ -257,7 +257,7 @@ 257 257 258 258 === Water === 259 259 260 -The BMS Main 3 can protect the battery from working in very high humidity conditions. 285 +The BMS Main 3 / BMS Main 2R can protect the battery from working in very high humidity conditions. 261 261 262 262 To change the protection parameters, select the "Protections → Water" section: 263 263 ... ... @@ -265,12 +265,12 @@ 265 265 266 266 In this section: 267 267 268 -* Enable – a flag to enable the protection;269 -* Maximum humidity, RH%; 270 -* Tolerant humidity, RH%; 271 -* Delay before setting the error, second; 272 -* Delay before clearing the error, second; 273 -* Lock – lock the error until the device is reset. 293 +* **Enable **– a flag to enable the protection; 294 +* **Maximum humidity**, RH%; 295 +* **Tolerant humidity**, RH%; 296 +* **Delay before setting the error**, second; 297 +* **Delay before clearing the error**, second; 298 +* **Lock **– lock the error until the device is reset. 274 274 275 275 As a result of the operation of the battery protection from water, the "Water" error is generated. 276 276 ... ... @@ -295,12 +295,12 @@ 295 295 296 296 In this section: 297 297 298 -* Enable – a flag to enable the protection; 299 -* Maximum temperature, °C; 300 -* Tolerant temperature, °C; 301 -* Delay before setting the error, second; 302 -* Delay before clearing the error, second; 303 -* Lock – lock the error until the device is reset. 323 +* **Enable **– a flag to enable the protection; 324 +* **Maximum temperature**, °C; 325 +* **Tolerant temperature**, °C; 326 +* **Delay before setting the error**, second; 327 +* **Delay before clearing the error**, second; 328 +* **Lock **– lock the error until the device is reset. 304 304 305 305 As a result of the operation of the protection from high temperatures of BMS Logic devices, the "High Logic temperature" is generated. 306 306 ... ... @@ -326,10 +326,10 @@ 326 326 327 327 In this section: 328 328 329 -* Enable – a flag to enable the protection; 330 -* Delay before setting the error, second; 331 -* Delay before clearing the error, second; 332 -* Lock – lock the error until the device is reset. 354 +* **Enable **– a flag to enable the protection; 355 +* **Delay before setting the error**, second; 356 +* **Delay before clearing the error**, second; 357 +* **Lock **– lock the error until the device is reset. 333 333 334 334 As a result of the protection from loss of communication with BMS Logic devices, the "Logic offline" error is generated. 335 335 ... ... @@ -354,11 +354,11 @@ 354 354 355 355 In this section: 356 356 357 -* Enable – a flag to enable the protection; 358 -* Number of cells – a number of cells connected to the BMS; 359 -* Delay before setting the error, millisecond; 360 -* Delay before clearing the error, second; 361 -* Lock – a flag to block the error until the device is restarted. 382 +* **Enable** – a flag to enable the protection; 383 +* **Number of cells** – a number of cells connected to the BMS; 384 +* **Delay before setting the error**, millisecond; 385 +* **Delay before clearing the error**, second; 386 +* **Lock **– a flag to block the error until the device is restarted. 362 362 363 363 As a result of the operation of the protection from the mismatch of the number of cells, the "Cell count error" is generated. 364 364 ... ... @@ -383,25 +383,25 @@ 383 383 384 384 In this section: 385 385 386 -* Enable – a flag to enable the protection; 387 -* Number of cells – a number of temperature sensors connected to the BMS; 388 -* Delay before setting the error, millisecond; 389 -* Delay before clearing the error, second; 390 -* Lock – a flag to block the error until the device is restarted. 411 +* **Enable **– a flag to enable the protection; 412 +* **Number of cells** – a number of temperature sensors connected to the BMS; 413 +* **Delay before setting the error**, millisecond; 414 +* **Delay before clearing the error**, second; 415 +* **Lock **– a flag to block the error until the device is restarted. 391 391 392 -As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensocount error" is generated. 417 +As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensor count error" is generated. 393 393 394 394 Error generation conditions: 395 395 396 -* the number of cells connected to the BMS is **not equal** to the “Number ofcells” value during the “Delay before setting the error” time.421 +* the number of temperature sensors connected to the BMS is **not equal** to the “Number of temperature sensors” value during the “Delay before setting the error” time. 397 397 398 398 Conditions for removing the error: 399 399 400 -* the number of cells connected to the BMS is **equal** to the “Number ofcells” value during the “Delay before clearing the error” time.425 +* the number of temperature sensors connected to the BMS is **equal** to the “Number of temperature sensors” value during the “Delay before clearing the error” time. 401 401 402 402 (% class="box warningmessage" %) 403 403 ((( 404 -If there is the " Cellcount error", the **“Critical error” **is generated**.**429 +If there is the "T-sensor count error", the **“Critical error” **is generated**.** 405 405 ))) 406 406 407 407 === Logic count === ... ... @@ -408,24 +408,28 @@ 408 408 409 409 To change the protection parameters from the mismatch of the number of BMS Logic devices to the set value, select the "Protections → Logic count” section: 410 410 411 -[[image:17 33328415732-163.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="110" width="800"]]436 +[[image:1762425434368-516.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]] 412 412 413 413 In this section: 414 414 415 -* Enable – a flag to enable the protection; 416 -* Logic count – a number of BMS Logic devices connected to the BMS Main; 417 -* Scan fast – a flag to scan BMS Logic devices fast (devices with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time); 418 -* Lock – lock the error until the device is reset. 440 +* **Enable **– a flag to enable the protection; 441 +* **Logic count** – a number of BMS Logic devices connected to the BMS Main; 442 +* **Scan fast** – a flag to scan BMS Logic devices fast (devices with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time); 443 +* **Delay before setting the error** – a delay before setting the error //during initialization//, millisecond; 444 +* **Delay before clearing the error **– a delay before clearing the error //during initialization//, second; 445 +* **Lock** – lock the error until the device is reset. 419 419 420 420 As a result of the operation of the protection from the mismatch of the number of BMS Logic devices, the "Logic count error" is generated. 421 421 422 422 Error generation conditions: 423 423 424 -* the number of BMS Logic devices connected to the BMS Main is **not equal** to the “Logic count” value. 451 +* during the initialization BMS Main 3 / BMS Main 2R have not found required number of BMS Logic devices during the "Delay before setting the error" time; 452 +* after the initialization the number of BMS Logic devices connected to the BMS Main is **not equal** to the “Logic count” value. 425 425 426 426 Conditions for removing the error: 427 427 428 -* the number of BMS Logic devices connected to the BMS Main is **equal** to the “Logic count” value. 456 +* during the initialization BMS Main 3 / BMS Main 2R have found required number of BMS Logic devices and the "Delay before setting the error" time has passed; 457 +* after the initialization the number of BMS Logic devices connected to the BMS Main is **equal** to the “Logic count” value. 429 429 430 430 (% class="box warningmessage" %) 431 431 ((( ... ... @@ -434,7 +434,7 @@ 434 434 435 435 === Short circuit === 436 436 437 -The BMS Main 3 device implements the protection of power circuits (contactors, power wires) against overheating caused by the flow of high current for a long time. 466 +The BMS Main 3 / BMS Main 2R device implements the protection of power circuits (contactors, power wires) against overheating caused by the flow of high current for a long time. 438 438 439 439 To change the protection parameters from short circuit, select the "Protections → Short circuit" section: 440 440 ... ... @@ -442,12 +442,12 @@ 442 442 443 443 In this section: 444 444 445 -* Level 1, 2, 3 – three protection levels. The following parameters are configured at each level: 446 -** Enable – a flag to enable the protection; 447 -** Maximum current, A; 448 -** Delay before setting the error, second; 449 -* Delay before clearing the error, second; 450 -* Lock – a flag to block the error until the device is restarted. 474 +* **Level 1, 2, 3** – three protection levels. The following parameters are configured at each level: 475 +** **Enable **– a flag to enable the protection; 476 +** **Maximum current**, A; 477 +** **Delay before setting the error**, second; 478 +* **Delay before clearing the error**, second; 479 +* **Lock **– a flag to block the error until the device is restarted. 451 451 452 452 If there is a short circuit, the "Short circuit" error is generated. 453 453 ... ... @@ -461,7 +461,7 @@ 461 461 462 462 === High contactor temperature === 463 463 464 -The BMS Main 3 device protects power contactors from overheating. To measure the temperature of the contactor, one of the thermistors connected to the X5 connector is used. 493 +The BMS Main 3 / BMS Main 2R device protects power contactors from overheating. To measure the temperature of the contactor, one of the thermistors connected to the X5 connector is used. 465 465 466 466 To change the overheating protection parameters of power contactors, select the "Protections → High contactor temperature" section: 467 467 ... ... @@ -469,13 +469,13 @@ 469 469 470 470 In this section: 471 471 472 -* Enable – a flag to enable the protection; 473 -* Thermistor – a selection of which cell thermistor will be used as contactor temperature sensor; 474 -* Maximum contactor temperature, °C; 475 -* Tolerant contactor temperature, °C; 476 -* Delay before setting the error, second; 477 -* Delay before clearing the error, second; 478 -* Lock – a flag to block the error until the device is restarted. 501 +* **Enable** – a flag to enable the protection; 502 +* **Thermistor **– a selection of which cell thermistor will be used as contactor temperature sensor; 503 +* **Maximum contactor temperature**, °C; 504 +* **Tolerant contactor temperature**, °C; 505 +* **Delay before setting the error**, second; 506 +* **Delay before clearing the error**, second; 507 +* **Lock **– a flag to block the error until the device is restarted. 479 479 480 480 If there is a contactor overheat, the "High contactor temperature" error is generated. 481 481 ... ... @@ -489,7 +489,7 @@ 489 489 490 490 === Current sensor === 491 491 492 -The BMS Main 3 device checks the current sensor connection circuits. The circuits are checked for breakage and short-circuit to the +5 V supply line. 521 +The BMS Main 3 / BMS Main 2R device checks the current sensor connection circuits. The circuits are checked for breakage and short-circuit to the +5 V supply line. 493 493 494 494 To change the test parameters of the current sensor connection circuits, select the "Protections → Current sensor" section: 495 495 ... ... @@ -497,13 +497,13 @@ 497 497 498 498 In this section: 499 499 500 -* Enable – a flag to enable the protection; 501 -* Maximum voltage, V; 502 -* Minimum voltage, V; 503 -* Voltage hysteresis – a hysteresis value to clear the error, V; 504 -* Delay before setting the error, second; 505 -* Delay before clearing the error, second; 506 -* Lock – a flag to block the error until the device is restarted. 529 +* **Enable **– a flag to enable the protection; 530 +* **Maximum voltage**, V; 531 +* **Minimum voltage**, V; 532 +* **Voltage hysteresis** – a hysteresis value to clear the error, V; 533 +* **Delay before setting the error**, second; 534 +* **Delay before clearing the error**, second; 535 +* **Lock **– a flag to block the error until the device is restarted. 507 507 508 508 If there is an open or short circuit connection of a current sensor, the "Current sensor error" is generated. 509 509 ... ... @@ -523,6 +523,11 @@ 523 523 524 524 === Power switch === 525 525 555 +(% class="box warningmessage" %) 556 +((( 557 +This section is not available on BMS Main 2R. 558 +))) 559 + 526 526 BMS Main 3 device checks the status of power switches that are used to control the contactors. To change the parameters of the power switch protection, select the "Protections → Power switch" section: 527 527 528 528 [[image:1733328461554-241.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="99" width="800"]] ... ... @@ -529,7 +529,7 @@ 529 529 530 530 In this section: 531 531 532 -* Delay before clearing the error, second; 566 +* **Delay before clearing the error**, second; 533 533 * Lock – a flag to block the error until the device is restarted. 534 534 535 535 The “Power switch error” occurs when the device detects a shortage in contactor coil control circuit or an overheating of the power switch. Error is removed when the temperature of power switch is normal during “Delay before clearing the error” time. ... ... @@ -541,6 +541,11 @@ 541 541 542 542 === Power fault === 543 543 578 +(% class="box warningmessage" %) 579 +((( 580 +This section is not available on BMS Main 2R. 581 +))) 582 + 544 544 BMS Main 3 device checks the status of CAN2, CAN3, RS-485-2 and Current sensors power supply. 545 545 546 546 (% class="box infomessage" %) ... ... @@ -571,7 +571,7 @@ 571 571 572 572 === Charge contactor cycles === 573 573 574 -The BMS Main 3 device protects the charging contactor against frequent switching. 613 +The BMS Main 3 / BMS Main 2R device protects the charging contactor against frequent switching. 575 575 576 576 To change the protection parameters against high frequency switching of the charging contactor, select the "Protections → Charge contactor cycles" section: 577 577 ... ... @@ -598,7 +598,7 @@ 598 598 599 599 === Discharge contactor cycles === 600 600 601 -The BMS Main 3 device protects the discharging contactor against frequent switching. 640 +The BMS Main 3 / BMS Main 2R device protects the discharging contactor against frequent switching. 602 602 603 603 To change the protection parameters against high frequency switching of the discharging contactor, select the "Protections → Discharging contactor cycles" section: 604 604 ... ... @@ -625,7 +625,7 @@ 625 625 626 626 === Temperature sensors === 627 627 628 -The BMS Main 3 device checks the temperature sensors connection circuits. The circuits are checked for breakage and short-circuit. 667 +The BMS Main 3 / BMS Main 2R device checks the temperature sensors connection circuits. The circuits are checked for breakage and short-circuit. 629 629 630 630 To change the protection parameters of the temperature sensors circuits, select the "Protections → Temperature sensors" section: 631 631 ... ... @@ -695,7 +695,7 @@ 695 695 696 696 === Stuck contactor === 697 697 698 -The BMS Main 3 device protects contactors against sticking. 737 +The BMS Main 3 / BMS Main 2R device protects contactors against sticking. 699 699 700 700 To change the protection parameters against sticking, select the "Protections → Stuck contactor" section: 701 701 ... ... @@ -721,7 +721,7 @@ 721 721 722 722 === Contactor feedback === 723 723 724 -The BMS Main 3 device can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, the feedback signal must be connected to the corresponding contactor feedback pin on the X3 header. 763 +The BMS Main 3 / BMS Main 2R device can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, the feedback signal must be connected to the corresponding contactor feedback pin on the X3 header. 725 725 726 726 To change the contactor feedback check parameters, select the "Protections → Contactor feedback" section: 727 727 ... ... @@ -745,7 +745,7 @@ 745 745 746 746 === Insulation === 747 747 748 -The BMS Main 3 device can detect a physical signal or CAN bus message from an external insulation monitoring device (such as Bender IR155, iso165C, BMD IMD) to monitor the insulation quality. 787 +The BMS Main 3 / BMS Main 2R device can detect a physical signal or CAN bus message from an external insulation monitoring device (such as Bender IR155, iso165C, BMD IMD) to monitor the insulation quality. 749 749 750 750 To change the insulation monitoring parameters, select the "Protections → Insulation" section: 751 751 ... ... @@ -771,7 +771,7 @@ 771 771 772 772 === HVIL === 773 773 774 -The BMS Main 3 allows to control the high voltage interlock loop by applying current to a testing loop and monitoring the difference between the measured current and the required value. 813 +The BMS Main 3 / BMS Main 2R allows to control the high voltage interlock loop by applying current to a testing loop and monitoring the difference between the measured current and the required value. 775 775 776 776 To change the HVIL measurement parameters, select the "Protections → HVIL" section: 777 777 ... ... @@ -795,6 +795,37 @@ 795 795 If there is the “HVIL error”, the **“Critical error”** is generated. 796 796 ))) 797 797 837 +=== Battery voltage === 838 + 839 +The BMS Main 3 / BMS Main 2R allows to control the difference between sum of all cell voltages and voltage measured before the contactors. 840 + 841 +To change the voltage difference check parameters, select the "Protections → Battery voltage" section: 842 + 843 +[[image:1755871661259-633.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]] 844 + 845 +In this section: 846 + 847 +* Enable – a flag to enable the protection; 848 +* Abnormal voltage difference – a maximum difference between sum of all cell voltages and voltage measured before the contactors (High voltage 1), V; 849 +* Delay before setting the error, second; 850 +* Delay before clearing the error, second; 851 +* Lock – a flag to block the error until the device is restarted. 852 + 853 +If there is a mismatch between voltages, "Battery voltage mismatch" error is generated. 854 + 855 +Error generation conditions: 856 + 857 +* difference between sum of all cell voltages and voltage measured before the contactors is **more **than "Abnormal voltage difference" value during "Delay before setting the error" time. 858 + 859 +Conditions for removing the error: 860 + 861 +* difference between sum of all cell voltages and voltage measured before the contactors is **less **than "Abnormal voltage difference" value during "Delay before clearing the error" time. 862 + 863 +(% class="box warningmessage" %) 864 +((( 865 +If there is the “Battery voltage mismatch” error, the **“Critical error”** is generated. 866 +))) 867 + 798 798 === Critical error === 799 799 800 800 Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault. ... ... @@ -801,7 +801,7 @@ 801 801 802 802 To change the critical error parameters, select the "Protections → Critical error" section: 803 803 804 -[[image:17 33328487100-898.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]]874 +[[image:1762775547945-129.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="117" width="800"]] 805 805 806 806 In this section: 807 807 ... ... @@ -808,6 +808,7 @@ 808 808 * Enable – a flag to enable the protection; 809 809 * Delay before setting the error, millisecond; 810 810 * Delay before clearing the error, second; 881 +* Errors 1, 2 to to ignore when setting the critical error; 811 811 * Lock – a flag to block the error until the device is restarted. 812 812 813 813 The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time.
- 1760434646517-885.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.4 KB - Content
- 1760436309214-414.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.4 KB - Content
- 1760437465709-702.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.4 KB - Content
- 1762425390154-843.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.8 KB - Content
- 1762425434368-516.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.8 KB - Content
- 1762775508522-157.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.9 KB - Content
- 1762775547945-129.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.4 KB - Content