Changes for page 3.4 Protections
Last modified by Admin on 2025/08/22 14:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -389,19 +389,19 @@ 389 389 * Delay before clearing the error, second; 390 390 * Lock – a flag to block the error until the device is restarted. 391 391 392 -As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensocount error" is generated. 392 +As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensor count error" is generated. 393 393 394 394 Error generation conditions: 395 395 396 -* the number of cells connected to the BMS is **not equal** to the “Number ofcells” value during the “Delay before setting the error” time.396 +* the number of temperature sensors connected to the BMS is **not equal** to the “Number of temperature sensors” value during the “Delay before setting the error” time. 397 397 398 398 Conditions for removing the error: 399 399 400 -* the number of cells connected to the BMS is **equal** to the “Number ofcells” value during the “Delay before clearing the error” time.400 +* the number of temperature sensors connected to the BMS is **equal** to the “Number of temperature sensors” value during the “Delay before clearing the error” time. 401 401 402 402 (% class="box warningmessage" %) 403 403 ((( 404 -If there is the " Cellcount error", the **“Critical error” **is generated**.**404 +If there is the "T-sensor count error", the **“Critical error” **is generated**.** 405 405 ))) 406 406 407 407 === Logic count === ... ... @@ -795,6 +795,37 @@ 795 795 If there is the “HVIL error”, the **“Critical error”** is generated. 796 796 ))) 797 797 798 +=== Battery voltage === 799 + 800 +The BMS Main 3 allows to control the difference between sum of all cell voltages and voltage measured before the contactors. 801 + 802 +To change the voltage difference check parameters, select the "Protections → Battery voltage" section: 803 + 804 +[[image:1755871661259-633.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]] 805 + 806 +In this section: 807 + 808 +* Enable – a flag to enable the protection; 809 +* Abnormal voltage difference – a maximum difference between sum of all cell voltages and voltage measured before the contactors (High voltage 1), V; 810 +* Delay before setting the error, second; 811 +* Delay before clearing the error, second; 812 +* Lock – a flag to block the error until the device is restarted. 813 + 814 +If there is a mismatch between voltages, "Battery voltage mismatch" error is generated. 815 + 816 +Error generation conditions: 817 + 818 +* difference between sum of all cell voltages and voltage measured before the contactors is **more **than "Abnormal voltage difference" value during "Delay before setting the error" time. 819 + 820 +Conditions for removing the error: 821 + 822 +* difference between sum of all cell voltages and voltage measured before the contactors is **less **than "Abnormal voltage difference" value during "Delay before clearing the error" time. 823 + 824 +(% class="box warningmessage" %) 825 +((( 826 +If there is the “Battery voltage mismatch” error, the **“Critical error”** is generated. 827 +))) 828 + 798 798 === Critical error === 799 799 800 800 Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault.