Changes for page 3.4 Protections
Last modified by Admin on 2025/08/22 14:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -375,6 +375,35 @@ 375 375 If there is the "Cell count error", the **“Critical error” **is generated**.** 376 376 ))) 377 377 378 +=== Temperature sensor count === 379 + 380 +To change the protection parameters from the mismatch of the number of temperature sensors to the set value, select the "Protections → Temperature sensor count" section: 381 + 382 +[[image:1755871582533-550.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 383 + 384 +In this section: 385 + 386 +* Enable – a flag to enable the protection; 387 +* Number of cells – a number of temperature sensors connected to the BMS; 388 +* Delay before setting the error, millisecond; 389 +* Delay before clearing the error, second; 390 +* Lock – a flag to block the error until the device is restarted. 391 + 392 +As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensor count error" is generated. 393 + 394 +Error generation conditions: 395 + 396 +* the number of temperature sensors connected to the BMS is **not equal** to the “Number of temperature sensors” value during the “Delay before setting the error” time. 397 + 398 +Conditions for removing the error: 399 + 400 +* the number of temperature sensors connected to the BMS is **equal** to the “Number of temperature sensors” value during the “Delay before clearing the error” time. 401 + 402 +(% class="box warningmessage" %) 403 +((( 404 +If there is the "T-sensor count error", the **“Critical error” **is generated**.** 405 +))) 406 + 378 378 === Logic count === 379 379 380 380 To change the protection parameters from the mismatch of the number of BMS Logic devices to the set value, select the "Protections → Logic count” section: ... ... @@ -766,6 +766,32 @@ 766 766 If there is the “HVIL error”, the **“Critical error”** is generated. 767 767 ))) 768 768 798 +=== Battery voltage === 799 + 800 +The BMS Main 3 allows to control the difference between sum of all cell voltages and voltage measured before the contactors. 801 + 802 +To change the HVIL measurement parameters, select the "Protections → Battery voltage" section: 803 + 804 +[[image:1755871661259-633.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]] 805 + 806 +In this section: 807 + 808 +* Enable – a flag to enable the protection; 809 +* Abnormal voltage difference – a maximum difference between sum of all cell voltages and voltage measured before the contactors (High voltage 1), V; 810 +* Delay before setting the error, second; 811 +* Delay before clearing the error, second; 812 +* Lock – a flag to block the error until the device is restarted. 813 + 814 +If there is a mismatch between voltages, "Battery voltage mismatch" error is generated. 815 + 816 +Error generation conditions: 817 + 818 +* difference between sum of all cell voltages and voltage measured before the contactors is **more **than "Abnormal voltage difference" value during "Delay before setting the error" time. 819 + 820 +Conditions for removing the error: 821 + 822 +* difference between sum of all cell voltages and voltage measured before the contactors is **less **than "Abnormal voltage difference" value during "Delay before clearing the error" time. 823 + 769 769 === Critical error === 770 770 771 771 Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault.
- 1755871661259-633.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.5 KB - Content