Changes for page 3.4 Protections
Last modified by Admin on 2025/08/22 14:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 5 removed)
Details
- Page properties
-
- Content
-
... ... @@ -94,7 +94,7 @@ 94 94 * Enable – a flag to enable the protection; 95 95 * Minimum cell voltage, V; 96 96 * Tolerant cell voltage, V; 97 -* Check the open circuit voltage instead of the actual voltage – a flag to use theU,,ocv,, (correcteddue to current and cell resistance) cell voltage;97 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 98 98 * Delay before setting the error, millisecond; 99 99 * Delay before clearing the error, second; 100 100 * Lock – a flag to block the error until the device is restarted. ... ... @@ -122,7 +122,7 @@ 122 122 * Enable – a flag to enable the protection; 123 123 * Maximum cell voltage, V; 124 124 * Tolerant cell voltage, V; 125 -* Check the open circuit voltage instead of the actual voltage – a flag to use theU,,ocv,, (correcteddue to current and cell resistance) cell voltage;125 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 126 126 * Delay before setting the error, millisecond; 127 127 * Delay before clearing the error, second; 128 128 * Lock – a flag to block the error until the device is restarted. ... ... @@ -321,14 +321,11 @@ 321 321 322 322 To change the protection parameters from loss of communication with BMS Logic devices, select the "Protections → Logic offline" section: 323 323 324 -[[image:17 55871522789-489.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]324 +[[image:1733328399416-818.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="86" width="800"]] 325 325 326 - 327 327 In this section: 328 328 329 329 * Enable – a flag to enable the protection; 330 -* Delay before setting the error, second; 331 -* Delay before clearing the error, second; 332 332 * Lock – lock the error until the device is reset. 333 333 334 334 As a result of the protection from loss of communication with BMS Logic devices, the "Logic offline" error is generated. ... ... @@ -799,7 +799,7 @@ 799 799 * Lock – a flag to block the error until the device is restarted; 800 800 * Errors 1, 2 to set the "Critical error" – bitfields to enable check of corresponding errors. 801 801 802 -The “General error”is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time.799 +The general error flag is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time. 803 803 804 804 The “General error” is cleared if there are no errors from the enabled errors during the “Delay before clearing the error” time. 805 805
- 1755870412909-992.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.5 KB - Content
- 1755870732669-803.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.2 KB - Content
- 1755871195329-366.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -16.0 KB - Content
- 1755871522789-489.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -16.0 KB - Content
- 1755871582533-550.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.2 KB - Content