... ... @@ -6,7 +6,7 @@
6 6  
7 7  The BMS Main 3 device continuously monitors the state of the cells, the external environment and, when detecting abnormalities, protects the battery and system components from damage.
8 8  
9 -(% class="box errormessage" %)
9 +(% class="box warningmessage" %)
10 10  (((
11 11  **Attention!**
12 12  Behavior of contactors at different errors is configured in **corresponding contactor settings**!
... ... @@ -55,7 +55,7 @@
55 55  
56 56  * Enable – a flag to enable the protection;
57 57  * Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A;
58 -* Region 1: Current difference – a value of maximum absolute current difference, A;
58 +* Region 1: Current difference – a value of maximum absolute current diffr, A;
59 59  * Region 2: Current difference – a value of maximum relative current excess, A;
60 60  * Delay before setting the error, millisecond;
61 61  * Delay before clearing the error, second;
... ... @@ -75,7 +75,7 @@
75 75  
76 76  * Enable – a flag to enable the protection;
77 77  * Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A;
78 -* Region 1: Current difference – a value of maximum absolute current difference, A;
78 +* Region 1: Current difference – a value of maximum absolute current diffr, A;
79 79  * Region 2: Current difference – a value of maximum relative current excess, A;
80 80  * Delay before setting the error, millisecond;
81 81  * Delay before clearing the error, second;
... ... @@ -94,7 +94,7 @@
94 94  * Enable – a flag to enable the protection;
95 95  * Minimum cell voltage, V;
96 96  * Tolerant cell voltage, V;
97 -* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage;
97 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance;
98 98  * Delay before setting the error, millisecond;
99 99  * Delay before clearing the error, second;
100 100  * Lock – a flag to block the error until the device is restarted.
... ... @@ -122,7 +122,7 @@
122 122  * Enable – a flag to enable the protection;
123 123  * Maximum cell voltage, V;
124 124  * Tolerant cell voltage, V;
125 -* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage;
125 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance;
126 126  * Delay before setting the error, millisecond;
127 127  * Delay before clearing the error, second;
128 128  * Lock – a flag to block the error until the device is restarted.
... ... @@ -321,14 +321,11 @@
321 321  
322 322  To change the protection parameters from loss of communication with BMS Logic devices, select the "Protections → Logic offline" section:
323 323  
324 -[[image:1755871522789-489.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
324 +[[image:1733328399416-818.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="86" width="800"]]
325 325  
326 -
327 327  In this section:
328 328  
329 329  * Enable – a flag to enable the protection;
330 -* Delay before setting the error, second;
331 -* Delay before clearing the error, second;
332 332  * Lock – lock the error until the device is reset.
333 333  
334 334  As a result of the protection from loss of communication with BMS Logic devices, the "Logic offline" error is generated.
... ... @@ -510,36 +510,6 @@
510 510  If there is the "Power switch error", the **“Critical error” **is generated.
511 511  )))
512 512  
513 -=== Power fault ===
514 -
515 -BMS Main 3 device checks the status of CAN2, CAN3, RS-485-2 and Current sensors power supply.
516 -
517 -(% class="box infomessage" %)
518 -(((
519 -**Note:** this error can be configured only under** "Service" account**.
520 -)))
521 -
522 -To change the parameters of the power fault error, select the "Protections → Power fault" section:
523 -
524 -[[image:1739284154410-676.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]]
525 -
526 -In this section:
527 -
528 -* Enable – a flag to enable the protection;
529 -* Delay before setting the error, millisecond;
530 -* Time to keep power off, millisecond;
531 -* Delay before clearing the error, millisecond;
532 -* Lock – a flag to block the error until the device is restarted.
533 -
534 -The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. After that BMS turns off the corresponding power supply for "Time to keep power off", then it tries to enable power again.
535 -
536 -Error is removed when the power consumption is normal during “Delay before clearing the error” time.
537 -
538 -(% class="box warningmessage" %)
539 -(((
540 -If there is the "Power fault", the **“Critical error” **is generated.
541 -)))
542 -
543 543  === Charge contactor cycles ===
544 544  
545 545  The BMS Main 3 device protects the charging contactor against frequent switching.
... ... @@ -757,10 +757,8 @@
757 757  * Source is ON: Upper current limit, A;
758 758  * Lock – a flag to block the error until the device is restarted.
759 759  
760 -If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated.
727 +If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored.
761 761  
762 -Error clears if interlock loop is being restored.
763 -
764 764  (% class="box warningmessage" %)
765 765  (((
766 766  If there is the “HVIL error”, the **“Critical error”** is generated.
... ... @@ -768,8 +768,6 @@
768 768  
769 769  === Critical error ===
770 770  
771 -Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault.
772 -
773 773  To change the critical error parameters, select the "Protections → Critical error" section:
774 774  
775 775  [[image:1733328487100-898.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]]
... ... @@ -781,10 +781,33 @@
781 781  * Delay before clearing the error, second;
782 782  * Lock – a flag to block the error until the device is restarted.
783 783  
784 -The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time.
747 +The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time:
785 785  
786 -The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
749 +* “Battery cover error”;
750 +* “Water”;
751 +* “Logic offline”;
752 +* “Cell count error”;
753 +* “ADC error”;
754 +* “Current sensor error”;
755 +* “Shunt offline”;
756 +* “Shunt error”;
757 +* “WDT reset”
758 +* “No temp. sensors”;
759 +* “Temperature sensor shorted”;
760 +* “Stuck contactor”;
761 +* “CH contactor feedback error”;
762 +* “DCH contactor feedback error”;
763 +* “Insulation fault”;
764 +* “PCH contactor feedback error”;
765 +* “CH/DCH contactor feedback error”;
766 +* “Main contactor feedback error”;
767 +* “High voltage fault”;
768 +* “Power switch error”;
769 +* “HVIL error”;
770 +* “Power fault”.
787 787  
772 +The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
773 +
788 788  === General error ===
789 789  
790 790  To change the general error parameters, select the "Protections → Critical error" section:
... ... @@ -799,7 +799,7 @@
799 799  * Lock – a flag to block the error until the device is restarted;
800 800  * Errors 1, 2 to set the "Critical error" – bitfields to enable check of corresponding errors.
801 801  
802 -The “General erroris generated if at least one of the enabled errors is generated during the “Delay before setting the error” time.
788 +The general error flag is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time.
803 803  
804 804  The “General error” is cleared if there are no errors from the enabled errors during the “Delay before clearing the error” time.
805 805  
1739284154410-676.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -20.4 KB
Content
1755870412909-992.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -20.5 KB
Content
1755870732669-803.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -17.2 KB
Content
1755871195329-366.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -16.0 KB
Content
1755871522789-489.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -16.0 KB
Content
1755871582533-550.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -17.2 KB
Content