Changes for page 3.4 Protections
Last modified by Admin on 2025/10/14 10:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -137,6 +137,12 @@ 137 137 138 138 * the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 139 139 140 +=== Cell imbalance === 141 + 142 +The BMS Main 3 device implements battery protection from too much cell imbalance. If balancing algorithm is not enough to compensate battery imbalance, then imbalance protection generates an error 143 + 144 +To change the battery protection parameters from low temperature, select the "Protections → Low temperature" section: 145 + 140 140 === Low temperature === 141 141 142 142 The BMS Main 3 device implements battery protection from too low temperature. ... ... @@ -375,6 +375,35 @@ 375 375 If there is the "Cell count error", the **“Critical error” **is generated**.** 376 376 ))) 377 377 384 +=== Temperature sensor count === 385 + 386 +To change the protection parameters from the mismatch of the number of temperature sensors to the set value, select the "Protections → Temperature sensor count" section: 387 + 388 +[[image:1755871582533-550.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 389 + 390 +In this section: 391 + 392 +* Enable – a flag to enable the protection; 393 +* Number of cells – a number of temperature sensors connected to the BMS; 394 +* Delay before setting the error, millisecond; 395 +* Delay before clearing the error, second; 396 +* Lock – a flag to block the error until the device is restarted. 397 + 398 +As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensor count error" is generated. 399 + 400 +Error generation conditions: 401 + 402 +* the number of temperature sensors connected to the BMS is **not equal** to the “Number of temperature sensors” value during the “Delay before setting the error” time. 403 + 404 +Conditions for removing the error: 405 + 406 +* the number of temperature sensors connected to the BMS is **equal** to the “Number of temperature sensors” value during the “Delay before clearing the error” time. 407 + 408 +(% class="box warningmessage" %) 409 +((( 410 +If there is the "T-sensor count error", the **“Critical error” **is generated**.** 411 +))) 412 + 378 378 === Logic count === 379 379 380 380 To change the protection parameters from the mismatch of the number of BMS Logic devices to the set value, select the "Protections → Logic count” section: ... ... @@ -766,6 +766,37 @@ 766 766 If there is the “HVIL error”, the **“Critical error”** is generated. 767 767 ))) 768 768 804 +=== Battery voltage === 805 + 806 +The BMS Main 3 allows to control the difference between sum of all cell voltages and voltage measured before the contactors. 807 + 808 +To change the voltage difference check parameters, select the "Protections → Battery voltage" section: 809 + 810 +[[image:1755871661259-633.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]] 811 + 812 +In this section: 813 + 814 +* Enable – a flag to enable the protection; 815 +* Abnormal voltage difference – a maximum difference between sum of all cell voltages and voltage measured before the contactors (High voltage 1), V; 816 +* Delay before setting the error, second; 817 +* Delay before clearing the error, second; 818 +* Lock – a flag to block the error until the device is restarted. 819 + 820 +If there is a mismatch between voltages, "Battery voltage mismatch" error is generated. 821 + 822 +Error generation conditions: 823 + 824 +* difference between sum of all cell voltages and voltage measured before the contactors is **more **than "Abnormal voltage difference" value during "Delay before setting the error" time. 825 + 826 +Conditions for removing the error: 827 + 828 +* difference between sum of all cell voltages and voltage measured before the contactors is **less **than "Abnormal voltage difference" value during "Delay before clearing the error" time. 829 + 830 +(% class="box warningmessage" %) 831 +((( 832 +If there is the “Battery voltage mismatch” error, the **“Critical error”** is generated. 833 +))) 834 + 769 769 === Critical error === 770 770 771 771 Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault.
- 1755871582533-550.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.2 KB - Content
- 1755871661259-633.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.5 KB - Content
- 1760434646517-885.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.4 KB - Content
- 1760436309214-414.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.4 KB - Content
- 1760437465709-702.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.4 KB - Content