Changes for page 3.4 Protections
Last modified by Admin on 2025/08/22 14:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -321,11 +321,14 @@ 321 321 322 322 To change the protection parameters from loss of communication with BMS Logic devices, select the "Protections → Logic offline" section: 323 323 324 -[[image:17 33328399416-818.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="86" width="800"]]324 +[[image:1755871522789-489.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]] 325 325 326 + 326 326 In this section: 327 327 328 328 * Enable – a flag to enable the protection; 330 +* Delay before setting the error, second; 331 +* Delay before clearing the error, second; 329 329 * Lock – lock the error until the device is reset. 330 330 331 331 As a result of the protection from loss of communication with BMS Logic devices, the "Logic offline" error is generated. ... ... @@ -372,6 +372,35 @@ 372 372 If there is the "Cell count error", the **“Critical error” **is generated**.** 373 373 ))) 374 374 378 +=== Temperature sensor count === 379 + 380 +To change the protection parameters from the mismatch of the number of temperature sensors to the set value, select the "Protections → Temperature sensor count" section: 381 + 382 +[[image:1755871582533-550.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 383 + 384 +In this section: 385 + 386 +* Enable – a flag to enable the protection; 387 +* Number of cells – a number of temperature sensors connected to the BMS; 388 +* Delay before setting the error, millisecond; 389 +* Delay before clearing the error, second; 390 +* Lock – a flag to block the error until the device is restarted. 391 + 392 +As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensocount error" is generated. 393 + 394 +Error generation conditions: 395 + 396 +* the number of cells connected to the BMS is **not equal** to the “Number of cells” value during the “Delay before setting the error” time. 397 + 398 +Conditions for removing the error: 399 + 400 +* the number of cells connected to the BMS is **equal** to the “Number of cells” value during the “Delay before clearing the error” time. 401 + 402 +(% class="box warningmessage" %) 403 +((( 404 +If there is the "Cell count error", the **“Critical error” **is generated**.** 405 +))) 406 + 375 375 === Logic count === 376 376 377 377 To change the protection parameters from the mismatch of the number of BMS Logic devices to the set value, select the "Protections → Logic count” section:
- 1755871582533-550.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.2 KB - Content