Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.bms-main-3.3\.Settings.WebHome1 +Battery management systems.BMS Main 3.3\. Configuration.WebHome - Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Settings=2 += Configuration = 3 3 4 4 (% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == Protections == ... ... @@ -294,9 +294,9 @@ 294 294 295 295 * a BMS Logic device temperature is less than the “Tolerant temperature” value. 296 296 297 -(% class="box warningmessage" %)297 +(% class="box infomessage" %) 298 298 ((( 299 - Overheated Logic devicesdo notbalancecells.299 +Cell balancing is disabled on Logic devices with high temperature. 300 300 ))) 301 301 302 302 === Logic offline === ... ... @@ -586,7 +586,7 @@ 586 586 587 587 (% class="box warningmessage" %) 588 588 ((( 589 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”** is generated and **all relays open.** 589 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”** is generated and **all relays open.** 590 590 ))) 591 591 592 592 === WDT reset === ... ... @@ -612,7 +612,7 @@ 612 612 If there is the "WDT reset" error, the **“Critical error” **is generated and **all relays open.** 613 613 ))) 614 614 615 -=== Unallowable charging ===615 +=== Unallowable charging === 616 616 617 617 The BMS can detect that the battery is charging through the discharging circuit and protectively open the discharging contactor to prevent unallowable battery operation. 618 618 ... ... @@ -642,7 +642,7 @@ 642 642 If there is the "Unallowable charging" error, the **discharging **contactor opens. 643 643 ))) 644 644 645 -=== Stuck contactor ===645 +=== Stuck contactor === 646 646 647 647 The BMS Main 3 device protects contactors against sticking. 648 648 ... ... @@ -692,7 +692,7 @@ 692 692 If there is the “Contactor feedback” error, the **“Critical error” **is generated and **all relays open.** 693 693 ))) 694 694 695 -=== Precharge ===695 +=== Precharge === 696 696 697 697 BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors. To change the pre-charge monitoring parameters, select the "Protections → Precharge" section: 698 698 ... ... @@ -714,7 +714,7 @@ 714 714 If there is the “Precharge error”, **charging **and **discharging **contactors open. 715 715 ))) 716 716 717 -=== Insulation ===717 +=== Insulation === 718 718 719 719 The BMS Main 3 device can detect a physical signal or CAN bus message from an external insulation monitoring device (such as Bender IR155, iso165C, BMD IMD) to monitor the insulation quality. 720 720