Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -55,7 +55,7 @@ 55 55 56 56 * Enable – a flag to enable the protection; 57 57 * Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 58 -* Region 1: Current difference – a value of maximum absolute current diff erence, A;58 +* Region 1: Current difference – a value of maximum absolute current diffr, A; 59 59 * Region 2: Current difference – a value of maximum relative current excess, A; 60 60 * Delay before setting the error, millisecond; 61 61 * Delay before clearing the error, second; ... ... @@ -75,7 +75,7 @@ 75 75 76 76 * Enable – a flag to enable the protection; 77 77 * Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 78 -* Region 1: Current difference – a value of maximum absolute current diff erence, A;78 +* Region 1: Current difference – a value of maximum absolute current diffr, A; 79 79 * Region 2: Current difference – a value of maximum relative current excess, A; 80 80 * Delay before setting the error, millisecond; 81 81 * Delay before clearing the error, second; ... ... @@ -528,7 +528,7 @@ 528 528 * Delay before clearing the error, millisecond; 529 529 * Lock – a flag to block the error until the device is restarted. 530 530 531 -The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. After that BMS turns off the corresponding power supply for "Time to keep power off", then it tries to enable power again.531 +The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. After that BMS turns off the corresponding power supply for the Time to keep power off 532 532 533 533 Error is removed when the power consumption is normal during “Delay before clearing the error” time. 534 534 ... ... @@ -754,10 +754,8 @@ 754 754 * Source is ON: Upper current limit, A; 755 755 * Lock – a flag to block the error until the device is restarted. 756 756 757 -If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. 757 +If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored. 758 758 759 -Error clears if interlock loop is being restored. 760 - 761 761 (% class="box warningmessage" %) 762 762 ((( 763 763 If there is the “HVIL error”, the **“Critical error”** is generated. ... ... @@ -765,7 +765,7 @@ 765 765 766 766 === Critical error === 767 767 768 -Some of the errors are system critical. A separate signal named "Critical error" indicates a BMSfault.766 +Some of the errors are system critical. A separate signal named "Critical error" indicates a system misbehaviour. 769 769 770 770 To change the critical error parameters, select the "Protections → Critical error" section: 771 771