Changes for page 3.4 Protections

Last modified by Admin on 2025/04/09 12:19

From version 26.3
edited by Admin
on 2025/02/24 14:09
Change comment: There is no comment for this version
To version 25.2
edited by Admin
on 2025/02/17 10:35
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -528,7 +528,7 @@
528 528  * Delay before clearing the error, millisecond;
529 529  * Lock – a flag to block the error until the device is restarted.
530 530  
531 -The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. After that BMS turns off the corresponding power supply for "Time to keep power off", then it tries to enable power again.
531 +The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. After that BMS turns off the corresponding power supply for the Time to keep power off
532 532  
533 533  Error is removed when the power consumption is normal during “Delay before clearing the error” time.
534 534  
... ... @@ -754,10 +754,8 @@
754 754  * Source is ON: Upper current limit, A;
755 755  * Lock – a flag to block the error until the device is restarted.
756 756  
757 -If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated.
757 +If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored.
758 758  
759 -Error clears if interlock loop is being restored.
760 -
761 761  (% class="box warningmessage" %)
762 762  (((
763 763  If there is the “HVIL error”, the **“Critical error”** is generated.
... ... @@ -765,7 +765,7 @@
765 765  
766 766  === Critical error ===
767 767  
768 -Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault.
766 +Some of the errors are system critical. A separate signal named "Critical error" indicates a system misbehaviour.
769 769  
770 770  To change the critical error parameters, select the "Protections → Critical error" section:
771 771