Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -513,7 +513,7 @@ 513 513 514 514 (% class="box infomessage" %) 515 515 ((( 516 -**Note:** this error can be configured only under** 516 +**Note:** this error can be configured only under** "Service" account**. 517 517 ))) 518 518 519 519 To change the parameters of the power fault error, select the "Protections → Power fault" section: ... ... @@ -522,16 +522,14 @@ 522 522 523 523 In this section: 524 524 525 -* Enable– a flagtonable theprotection;525 +* Delay before clearing the error, second; 526 526 * Delay before setting the error, millisecond; 527 527 * Time to keep power off, millisecond; 528 528 * Delay before clearing the error, millisecond; 529 529 * Lock – a flag to block the error until the device is restarted. 530 530 531 -The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. Afterthat BMS turnsoffthecorrespondingpower supply for"Timetokeeppoweroff", thenit triestoenablepoweragain.531 +The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. Error is removed when the power consumption is normal during “Delay before clearing the error” time. 532 532 533 -Error is removed when the power consumption is normal during “Delay before clearing the error” time. 534 - 535 535 (% class="box warningmessage" %) 536 536 ((( 537 537 If there is the "Power fault", the **“Critical error” **is generated. ... ... @@ -754,10 +754,8 @@ 754 754 * Source is ON: Upper current limit, A; 755 755 * Lock – a flag to block the error until the device is restarted. 756 756 757 -If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. 755 +If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored. 758 758 759 -Error clears if interlock loop is being restored. 760 - 761 761 (% class="box warningmessage" %) 762 762 ((( 763 763 If there is the “HVIL error”, the **“Critical error”** is generated. ... ... @@ -765,7 +765,7 @@ 765 765 766 766 === Critical error === 767 767 768 -Some of the errors are system critical. A separate signal named "Critical error" indicates a BMSfault.764 +Some of the errors are system critical. A separate signal named "Critical error" indicates a system misbehaviour. 769 769 770 770 To change the critical error parameters, select the "Protections → Critical error" section: 771 771 ... ... @@ -778,9 +778,9 @@ 778 778 * Delay before clearing the error, second; 779 779 * Lock – a flag to block the error until the device is restarted. 780 780 781 -The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time:777 +The "Critical error" flag is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time: 782 782 783 -The “Critical error "signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time.779 +The “Critical error” flag is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 784 784 785 785 === General error === 786 786