Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -511,11 +511,6 @@ 511 511 512 512 BMS Main 3 device checks the status of CAN2, CAN3, RS-485-2 and Current sensors power supply. 513 513 514 -(% class="box infomessage" %) 515 -((( 516 -**Note:** this error can be configured only under** "Service" account**. 517 -))) 518 - 519 519 To change the parameters of the power fault error, select the "Protections → Power fault" section: 520 520 521 521 [[image:1739284154410-676.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]] ... ... @@ -522,16 +522,14 @@ 522 522 523 523 In this section: 524 524 525 -* Enable– a flagtonable theprotection;520 +* Delay before clearing the error, second; 526 526 * Delay before setting the error, millisecond; 527 527 * Time to keep power off, millisecond; 528 528 * Delay before clearing the error, millisecond; 529 529 * Lock – a flag to block the error until the device is restarted. 530 530 531 -The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. Afterthat BMS turnsoffthecorrespondingpower supply for"Timetokeeppoweroff", thenit triestoenablepoweragain.526 +The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. Error is removed when the power consumption is normal during “Delay before clearing the error” time. 532 532 533 -Error is removed when the power consumption is normal during “Delay before clearing the error” time. 534 - 535 535 (% class="box warningmessage" %) 536 536 ((( 537 537 If there is the "Power fault", the **“Critical error” **is generated. ... ... @@ -754,10 +754,8 @@ 754 754 * Source is ON: Upper current limit, A; 755 755 * Lock – a flag to block the error until the device is restarted. 756 756 757 -If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. 750 +If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored. 758 758 759 -Error clears if interlock loop is being restored. 760 - 761 761 (% class="box warningmessage" %) 762 762 ((( 763 763 If there is the “HVIL error”, the **“Critical error”** is generated. ... ... @@ -765,8 +765,6 @@ 765 765 766 766 === Critical error === 767 767 768 -Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault. 769 - 770 770 To change the critical error parameters, select the "Protections → Critical error" section: 771 771 772 772 [[image:1733328487100-898.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]] ... ... @@ -778,10 +778,33 @@ 778 778 * Delay before clearing the error, second; 779 779 * Lock – a flag to block the error until the device is restarted. 780 780 781 -The "Critical error"signal is generated if at least one of thecritical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signalsanderrors.WebHome||anchor="HErrors"]])is generated during the “Delay before setting the error” time:770 +The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time: 782 782 783 -The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 772 +* “Battery cover error”; 773 +* “Water”; 774 +* “Logic offline”; 775 +* “Cell count error”; 776 +* “ADC error”; 777 +* “Current sensor error”; 778 +* “Shunt offline”; 779 +* “Shunt error”; 780 +* “WDT reset” 781 +* “No temp. sensors”; 782 +* “Temperature sensor shorted”; 783 +* “Stuck contactor”; 784 +* “CH contactor feedback error”; 785 +* “DCH contactor feedback error”; 786 +* “Insulation fault”; 787 +* “PCH contactor feedback error”; 788 +* “CH/DCH contactor feedback error”; 789 +* “Main contactor feedback error”; 790 +* “High voltage fault”; 791 +* “Power switch error”; 792 +* “HVIL error”; 793 +* “Power fault”. 784 784 795 +The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 796 + 785 785 === General error === 786 786 787 787 To change the general error parameters, select the "Protections → Critical error" section: