55 55  
56 56  * Enable – a flag to enable the protection;
57 57  * Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A;
58 -* Region 1: Current difference – a value of maximum absolute current diffr, A;
58 +* Region 1: Current difference – a value of maximum absolute current difference, A;
59 59  * Region 2: Current difference – a value of maximum relative current excess, A;
60 60  * Delay before setting the error, millisecond;
61 61  * Delay before clearing the error, second;
... ... @@ -75,7 +75,7 @@
75 75  
76 76  * Enable – a flag to enable the protection;
77 77  * Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A;
78 -* Region 1: Current difference – a value of maximum absolute current diffr, A;
78 +* Region 1: Current difference – a value of maximum absolute current difference, A;
79 79  * Region 2: Current difference – a value of maximum relative current excess, A;
80 80  * Delay before setting the error, millisecond;
81 81  * Delay before clearing the error, second;
... ... @@ -94,7 +94,7 @@
94 94  * Enable – a flag to enable the protection;
95 95  * Minimum cell voltage, V;
96 96  * Tolerant cell voltage, V;
97 -* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance;
97 +* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage;
98 98  * Delay before setting the error, millisecond;
99 99  * Delay before clearing the error, second;
100 100  * Lock – a flag to block the error until the device is restarted.
... ... @@ -122,7 +122,7 @@
122 122  * Enable – a flag to enable the protection;
123 123  * Maximum cell voltage, V;
124 124  * Tolerant cell voltage, V;
125 -* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance;
125 +* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage;
126 126  * Delay before setting the error, millisecond;
127 127  * Delay before clearing the error, second;
128 128  * Lock – a flag to block the error until the device is restarted.
... ... @@ -321,11 +321,14 @@
321 321  
322 322  To change the protection parameters from loss of communication with BMS Logic devices, select the "Protections → Logic offline" section:
323 323  
324 -[[image:1733328399416-818.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="86" width="800"]]
324 +[[image:1755871522789-489.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
325 325  
326 +
326 326  In this section:
327 327  
328 328  * Enable – a flag to enable the protection;
330 +* Delay before setting the error, second;
331 +* Delay before clearing the error, second;
329 329  * Lock – lock the error until the device is reset.
330 330  
331 331  As a result of the protection from loss of communication with BMS Logic devices, the "Logic offline" error is generated.
... ... @@ -372,6 +372,35 @@
372 372  If there is the "Cell count error", the **“Critical error” **is generated**.**
373 373  )))
374 374  
378 +=== Temperature sensor count ===
379 +
380 +To change the protection parameters from the mismatch of the number of temperature sensors to the set value, select the "Protections → Temperature sensor count" section:
381 +
382 +[[image:1755871582533-550.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]]
383 +
384 +In this section:
385 +
386 +* Enable – a flag to enable the protection;
387 +* Number of cells – a number of temperature sensors connected to the BMS;
388 +* Delay before setting the error, millisecond;
389 +* Delay before clearing the error, second;
390 +* Lock – a flag to block the error until the device is restarted.
391 +
392 +As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensor count error" is generated.
393 +
394 +Error generation conditions:
395 +
396 +* the number of temperature sensors connected to the BMS is **not equal** to the “Number of temperature sensors” value during the “Delay before setting the error” time.
397 +
398 +Conditions for removing the error:
399 +
400 +* the number of temperature sensors connected to the BMS is **equal** to the “Number of temperature sensors” value during the “Delay before clearing the error” time.
401 +
402 +(% class="box warningmessage" %)
403 +(((
404 +If there is the "T-sensor count error", the **“Critical error” **is generated**.**
405 +)))
406 +
375 375  === Logic count ===
376 376  
377 377  To change the protection parameters from the mismatch of the number of BMS Logic devices to the set value, select the "Protections → Logic count” section:
... ... @@ -528,7 +528,7 @@
528 528  * Delay before clearing the error, millisecond;
529 529  * Lock – a flag to block the error until the device is restarted.
530 530  
531 -The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. After that BMS turns off the corresponding power supply for the Time to keep power off
563 +The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. After that BMS turns off the corresponding power supply for "Time to keep power off", then it tries to enable power again.
532 532  
533 533  Error is removed when the power consumption is normal during “Delay before clearing the error” time.
534 534  
... ... @@ -754,16 +754,49 @@
754 754  * Source is ON: Upper current limit, A;
755 755  * Lock – a flag to block the error until the device is restarted.
756 756  
757 -If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored.
789 +If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated.
758 758  
791 +Error clears if interlock loop is being restored.
792 +
759 759  (% class="box warningmessage" %)
760 760  (((
761 761  If there is the “HVIL error”, the **“Critical error”** is generated.
762 762  )))
763 763  
798 +=== Battery voltage ===
799 +
800 +The BMS Main 3 allows to control the difference between sum of all cell voltages and voltage measured before the contactors.
801 +
802 +To change the voltage difference check parameters, select the "Protections → Battery voltage" section:
803 +
804 +[[image:1755871661259-633.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]]
805 +
806 +In this section:
807 +
808 +* Enable – a flag to enable the protection;
809 +* Abnormal voltage difference – a maximum difference between sum of all cell voltages and voltage measured before the contactors (High voltage 1), V;
810 +* Delay before setting the error, second;
811 +* Delay before clearing the error, second;
812 +* Lock – a flag to block the error until the device is restarted.
813 +
814 +If there is a mismatch between voltages, "Battery voltage mismatch" error is generated.
815 +
816 +Error generation conditions:
817 +
818 +* difference between sum of all cell voltages and voltage measured before the contactors is **more **than "Abnormal voltage difference" value during "Delay before setting the error" time.
819 +
820 +Conditions for removing the error:
821 +
822 +* difference between sum of all cell voltages and voltage measured before the contactors is **less **than "Abnormal voltage difference" value during "Delay before clearing the error" time.
823 +
824 +(% class="box warningmessage" %)
825 +(((
826 +If there is the “Battery voltage mismatch” error, the **“Critical error”** is generated.
827 +)))
828 +
764 764  === Critical error ===
765 765  
766 -Some of the errors are system critical. A separate signal named "Critical error" indicates a system misbehaviour.
831 +Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault.
767 767  
768 768  To change the critical error parameters, select the "Protections → Critical error" section:
769 769  
... ... @@ -776,7 +776,7 @@
776 776  * Delay before clearing the error, second;
777 777  * Lock – a flag to block the error until the device is restarted.
778 778  
779 -The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time:
844 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time.
780 780  
781 781  The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
782 782  
... ... @@ -794,7 +794,7 @@
794 794  * Lock – a flag to block the error until the device is restarted;
795 795  * Errors 1, 2 to set the "Critical error" – bitfields to enable check of corresponding errors.
796 796  
797 -The general error flag is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time.
862 +The “General erroris generated if at least one of the enabled errors is generated during the “Delay before setting the error” time.
798 798  
799 799  The “General error” is cleared if there are no errors from the enabled errors during the “Delay before clearing the error” time.
800 800  
1755870412909-992.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +20.5 KB
Content
1755870732669-803.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +17.2 KB
Content
1755871195329-366.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +16.0 KB
Content
1755871522789-489.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +16.0 KB
Content
1755871582533-550.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +17.2 KB
Content
1755871661259-633.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +20.5 KB
Content