Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -55,7 +55,7 @@ 55 55 56 56 * Enable – a flag to enable the protection; 57 57 * Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 58 -* Region 1: Current difference – a value of maximum absolute current diffr, A; 58 +* Region 1: Current difference – a value of maximum absolute current difference, A; 59 59 * Region 2: Current difference – a value of maximum relative current excess, A; 60 60 * Delay before setting the error, millisecond; 61 61 * Delay before clearing the error, second; ... ... @@ -75,7 +75,7 @@ 75 75 76 76 * Enable – a flag to enable the protection; 77 77 * Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 78 -* Region 1: Current difference – a value of maximum absolute current diffr, A; 78 +* Region 1: Current difference – a value of maximum absolute current difference, A; 79 79 * Region 2: Current difference – a value of maximum relative current excess, A; 80 80 * Delay before setting the error, millisecond; 81 81 * Delay before clearing the error, second; ... ... @@ -528,7 +528,7 @@ 528 528 * Delay before clearing the error, millisecond; 529 529 * Lock – a flag to block the error until the device is restarted. 530 530 531 -The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. After that BMS turns off the corresponding power supply for theTime to keep power off531 +The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. After that BMS turns off the corresponding power supply for "Time to keep power off", then it tries to enable power again. 532 532 533 533 Error is removed when the power consumption is normal during “Delay before clearing the error” time. 534 534 ... ... @@ -754,8 +754,10 @@ 754 754 * Source is ON: Upper current limit, A; 755 755 * Lock – a flag to block the error until the device is restarted. 756 756 757 -If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored.757 +If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. 758 758 759 +Error clears if interlock loop is being restored. 760 + 759 759 (% class="box warningmessage" %) 760 760 ((( 761 761 If there is the “HVIL error”, the **“Critical error”** is generated. ... ... @@ -763,7 +763,7 @@ 763 763 764 764 === Critical error === 765 765 766 -Some of the errors are system critical. A separate signal named "Critical error" indicates a systemmisbehaviour.768 +Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault. 767 767 768 768 To change the critical error parameters, select the "Protections → Critical error" section: 769 769 ... ... @@ -776,7 +776,7 @@ 776 776 * Delay before clearing the error, second; 777 777 * Lock – a flag to block the error until the device is restarted. 778 778 779 -The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time :781 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time. 780 780 781 781 The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 782 782 ... ... @@ -794,7 +794,7 @@ 794 794 * Lock – a flag to block the error until the device is restarted; 795 795 * Errors 1, 2 to set the "Critical error" – bitfields to enable check of corresponding errors. 796 796 797 -The general errorflagis generated if at least one of the enabled errors is generated during the “Delay before setting the error” time.799 +The “General error”is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time. 798 798 799 799 The “General error” is cleared if there are no errors from the enabled errors during the “Delay before clearing the error” time. 800 800