Changes for page 3.4 Protections

Last modified by Admin on 2025/08/22 14:36

From version 25.2
edited by Admin
on 2025/02/17 10:35
Change comment: There is no comment for this version
To version 23.3
edited by Admin
on 2025/02/11 14:43
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -513,7 +513,7 @@
513 513  
514 514  (% class="box infomessage" %)
515 515  (((
516 -**Note:** this error can be configured only under** "Service" account**.
516 +**Note:** this error can be configured only under** "Service" account**.
517 517  )))
518 518  
519 519  To change the parameters of the power fault error, select the "Protections → Power fault" section:
... ... @@ -522,16 +522,14 @@
522 522  
523 523  In this section:
524 524  
525 -* Enable – a flag to enable the protection;
525 +* Delay before clearing the error, second;
526 526  * Delay before setting the error, millisecond;
527 527  * Time to keep power off, millisecond;
528 528  * Delay before clearing the error, millisecond;
529 529  * Lock – a flag to block the error until the device is restarted.
530 530  
531 -The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. After that BMS turns off the corresponding power supply for the Time to keep power off
531 +The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. Error is removed when the power consumption is normal during “Delay before clearing the error” time.
532 532  
533 -Error is removed when the power consumption is normal during “Delay before clearing the error” time.
534 -
535 535  (% class="box warningmessage" %)
536 536  (((
537 537  If there is the "Power fault", the **“Critical error” **is generated.
... ... @@ -763,8 +763,6 @@
763 763  
764 764  === Critical error ===
765 765  
766 -Some of the errors are system critical. A separate signal named "Critical error" indicates a system misbehaviour.
767 -
768 768  To change the critical error parameters, select the "Protections → Critical error" section:
769 769  
770 770  [[image:1733328487100-898.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]]
... ... @@ -776,9 +776,9 @@
776 776  * Delay before clearing the error, second;
777 777  * Lock – a flag to block the error until the device is restarted.
778 778  
779 -The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time:
775 +The "Critical error" flag is generated if at least one of the critical errors (see [[Battery controllers: signals and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time:
780 780  
781 -The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
777 +The “Critical error flag is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
782 782  
783 783  === General error ===
784 784