Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -509,32 +509,23 @@ 509 509 510 510 === Power fault === 511 511 512 -BMS Main 3 device checks the status of CAN2, CAN3, RS-4 85-2andCurrentsensorspowersupply.512 +BMS Main 3 device checks the status of power supply of CAN2, CAN3, RS-4. To change the parameters of the power fault error, select the "Protections → Power fault" section: 513 513 514 -(% class="box infomessage" %) 515 -((( 516 -**Note:** this error can be configured only under** "Service" account**. 517 -))) 518 - 519 -To change the parameters of the power fault error, select the "Protections → Power fault" section: 520 - 521 521 [[image:1739284154410-676.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]] 522 522 523 523 In this section: 524 524 525 -* Enable– a flagtonable theprotection;518 +* Delay before clearing the error, second; 526 526 * Delay before setting the error, millisecond; 527 527 * Time to keep power off, millisecond; 528 528 * Delay before clearing the error, millisecond; 529 529 * Lock – a flag to block the error until the device is restarted. 530 530 531 -The “Power fault” occurs when the device detects a shortage or highpower consumption in power suppliesmentionedabove.AfterthatBMS turnsoffthe correspondingpower supply fortheTimeto keeppowerff524 +The “Power fault” occurs when the device detects a shortage in contactor coil control circuit or an overheating of the power switch. Error is removed when the temperature of power switch is normal during “Delay before clearing the error” time. 532 532 533 -Error is removed when the power consumption is normal during “Delay before clearing the error” time. 534 - 535 535 (% class="box warningmessage" %) 536 536 ((( 537 -If there is the "Power fault", the **“Critical error” **is generated.528 +If there is the "Power switch error", the **“Critical error” **is generated. 538 538 ))) 539 539 540 540 === Charge contactor cycles === ... ... @@ -763,8 +763,6 @@ 763 763 764 764 === Critical error === 765 765 766 -Some of the errors are system critical. A separate signal named "Critical error" indicates a system misbehaviour. 767 - 768 768 To change the critical error parameters, select the "Protections → Critical error" section: 769 769 770 770 [[image:1733328487100-898.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]] ... ... @@ -776,10 +776,33 @@ 776 776 * Delay before clearing the error, second; 777 777 * Lock – a flag to block the error until the device is restarted. 778 778 779 -The "Critical error"signal is generated if at least one of thecritical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signalsanderrors.WebHome||anchor="HErrors"]])is generated during the “Delay before setting the error” time:768 +The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time: 780 780 781 -The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 770 +* “Battery cover error”; 771 +* “Water”; 772 +* “Logic offline”; 773 +* “Cell count error”; 774 +* “ADC error”; 775 +* “Current sensor error”; 776 +* “Shunt offline”; 777 +* “Shunt error”; 778 +* “WDT reset” 779 +* “No temp. sensors”; 780 +* “Temperature sensor shorted”; 781 +* “Stuck contactor”; 782 +* “CH contactor feedback error”; 783 +* “DCH contactor feedback error”; 784 +* “Insulation fault”; 785 +* “PCH contactor feedback error”; 786 +* “CH/DCH contactor feedback error”; 787 +* “Main contactor feedback error”; 788 +* “High voltage fault”; 789 +* “Power switch error”; 790 +* “HVIL error”; 791 +* “Power fault”. 782 782 793 +The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 794 + 783 783 === General error === 784 784 785 785 To change the general error parameters, select the "Protections → Critical error" section: