... ... @@ -507,36 +507,6 @@
507 507  If there is the "Power switch error", the **“Critical error” **is generated.
508 508  )))
509 509  
510 -=== Power fault ===
511 -
512 -BMS Main 3 device checks the status of CAN2, CAN3, RS-485-2 and Current sensors power supply.
513 -
514 -(% class="box infomessage" %)
515 -(((
516 -**Note:** this error can be configured only under** "Service" account**.
517 -)))
518 -
519 -To change the parameters of the power fault error, select the "Protections → Power fault" section:
520 -
521 -[[image:1739284154410-676.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]]
522 -
523 -In this section:
524 -
525 -* Enable – a flag to enable the protection;
526 -* Delay before setting the error, millisecond;
527 -* Time to keep power off, millisecond;
528 -* Delay before clearing the error, millisecond;
529 -* Lock – a flag to block the error until the device is restarted.
530 -
531 -The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. After that BMS turns off the corresponding power supply for the Time to keep power off
532 -
533 -Error is removed when the power consumption is normal during “Delay before clearing the error” time.
534 -
535 -(% class="box warningmessage" %)
536 -(((
537 -If there is the "Power fault", the **“Critical error” **is generated.
538 -)))
539 -
540 540  === Charge contactor cycles ===
541 541  
542 542  The BMS Main 3 device protects the charging contactor against frequent switching.
... ... @@ -763,8 +763,6 @@
763 763  
764 764  === Critical error ===
765 765  
766 -Some of the errors are system critical. A separate signal named "Critical error" indicates a system misbehaviour.
767 -
768 768  To change the critical error parameters, select the "Protections → Critical error" section:
769 769  
770 770  [[image:1733328487100-898.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]]
... ... @@ -776,10 +776,33 @@
776 776  * Delay before clearing the error, second;
777 777  * Lock – a flag to block the error until the device is restarted.
778 778  
779 -The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time:
747 +The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time:
780 780  
781 -The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
749 +* “Battery cover error”;
750 +* “Water”;
751 +* “Logic offline”;
752 +* “Cell count error”;
753 +* “ADC error”;
754 +* “Current sensor error”;
755 +* “Shunt offline”;
756 +* “Shunt error”;
757 +* “WDT reset”
758 +* “No temp. sensors”;
759 +* “Temperature sensor shorted”;
760 +* “Stuck contactor”;
761 +* “CH contactor feedback error”;
762 +* “DCH contactor feedback error”;
763 +* “Insulation fault”;
764 +* “PCH contactor feedback error”;
765 +* “CH/DCH contactor feedback error”;
766 +* “Main contactor feedback error”;
767 +* “High voltage fault”;
768 +* “Power switch error”;
769 +* “HVIL error”;
770 +* “Power fault”.
782 782  
772 +The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
773 +
783 783  === General error ===
784 784  
785 785  To change the general error parameters, select the "Protections → Critical error" section:
1739284154410-676.png