Changes for page 3.4 Protections

Last modified by Admin on 2025/04/09 12:19

From version 25.1
edited by Admin
on 2025/02/11 14:48
Change comment: There is no comment for this version
To version 25.2
edited by Admin
on 2025/02/17 10:35
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -522,14 +522,16 @@
522 522  
523 523  In this section:
524 524  
525 -* Delay before clearing the error, second;
525 +* Enable – a flag to enable the protection;
526 526  * Delay before setting the error, millisecond;
527 527  * Time to keep power off, millisecond;
528 528  * Delay before clearing the error, millisecond;
529 529  * Lock – a flag to block the error until the device is restarted.
530 530  
531 -The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. Error is removed when the power consumption is normal during “Delay before clearing the error” time.
531 +The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. After that BMS turns off the corresponding power supply for the Time to keep power off
532 532  
533 +Error is removed when the power consumption is normal during “Delay before clearing the error” time.
534 +
533 533  (% class="box warningmessage" %)
534 534  (((
535 535  If there is the "Power fault", the **“Critical error” **is generated.