... ... @@ -513,7 +513,7 @@
513 513  
514 514  (% class="box infomessage" %)
515 515  (((
516 -**Note:** this error can be configured only under** "Service" account**.
516 +**Note:** this error can be configured only under** "Service" account**.
517 517  )))
518 518  
519 519  To change the parameters of the power fault error, select the "Protections → Power fault" section:
... ... @@ -522,14 +522,16 @@
522 522  
523 523  In this section:
524 524  
525 -* Delay before clearing the error, second;
525 +* Enable – a flag to enable the protection;
526 526  * Delay before setting the error, millisecond;
527 527  * Time to keep power off, millisecond;
528 528  * Delay before clearing the error, millisecond;
529 529  * Lock – a flag to block the error until the device is restarted.
530 530  
531 -The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. Error is removed when the power consumption is normal during “Delay before clearing the error” time.
531 +The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. After that BMS turns off the corresponding power supply for "Time to keep power off", then it tries to enable power again.
532 532  
533 +Error is removed when the power consumption is normal during “Delay before clearing the error” time.
534 +
533 533  (% class="box warningmessage" %)
534 534  (((
535 535  If there is the "Power fault", the **“Critical error” **is generated.
... ... @@ -752,8 +752,10 @@
752 752  * Source is ON: Upper current limit, A;
753 753  * Lock – a flag to block the error until the device is restarted.
754 754  
755 -If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored.
757 +If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated.
756 756  
759 +Error clears if interlock loop is being restored.
760 +
757 757  (% class="box warningmessage" %)
758 758  (((
759 759  If there is the “HVIL error”, the **“Critical error”** is generated.
... ... @@ -761,7 +761,7 @@
761 761  
762 762  === Critical error ===
763 763  
764 -Some of the errors are system critical. A separate signal named "Critical error" indicates a system misbehaviour.
768 +Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault.
765 765  
766 766  To change the critical error parameters, select the "Protections → Critical error" section:
767 767  
... ... @@ -774,9 +774,9 @@
774 774  * Delay before clearing the error, second;
775 775  * Lock – a flag to block the error until the device is restarted.
776 776  
777 -The "Critical error" flag is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time:
781 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time:
778 778  
779 -The “Critical error flag is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
783 +The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
780 780  
781 781  === General error ===
782 782