Changes for page 3.4 Protections

Last modified by Admin on 2025/04/09 12:19

From version 23.4
edited by Admin
on 2025/02/11 14:45
Change comment: There is no comment for this version
To version 23.2
edited by Admin
on 2025/02/11 14:36
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -761,8 +761,6 @@
761 761  
762 762  === Critical error ===
763 763  
764 -Some of the errors are system critical. A separate signal named "Critical error" indicates a system misbehaviour.
765 -
766 766  To change the critical error parameters, select the "Protections → Critical error" section:
767 767  
768 768  [[image:1733328487100-898.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]]
... ... @@ -774,10 +774,33 @@
774 774  * Delay before clearing the error, second;
775 775  * Lock – a flag to block the error until the device is restarted.
776 776  
777 -The "Critical error" flag is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time:
775 +The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time:
778 778  
779 -The “Critical error” flag is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
777 +* “Battery cover error”;
778 +* “Water”;
779 +* “Logic offline”;
780 +* “Cell count error”;
781 +* “ADC error”;
782 +* “Current sensor error”;
783 +* “Shunt offline”;
784 +* “Shunt error”;
785 +* “WDT reset”
786 +* “No temp. sensors”;
787 +* “Temperature sensor shorted”;
788 +* “Stuck contactor”;
789 +* “CH contactor feedback error”;
790 +* “DCH contactor feedback error”;
791 +* “Insulation fault”;
792 +* “PCH contactor feedback error”;
793 +* “CH/DCH contactor feedback error”;
794 +* “Main contactor feedback error”;
795 +* “High voltage fault”;
796 +* “Power switch error”;
797 +* “HVIL error”;
798 +* “Power fault”.
780 780  
800 +The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
801 +
781 781  === General error ===
782 782  
783 783  To change the general error parameters, select the "Protections → Critical error" section: