Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -511,11 +511,6 @@ 511 511 512 512 BMS Main 3 device checks the status of CAN2, CAN3, RS-485-2 and Current sensors power supply. 513 513 514 -(% class="box infomessage" %) 515 -((( 516 -**Note:** this error can be configured only under** "Service" account**. 517 -))) 518 - 519 519 To change the parameters of the power fault error, select the "Protections → Power fault" section: 520 520 521 521 [[image:1739284154410-676.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]] ... ... @@ -528,11 +528,11 @@ 528 528 * Delay before clearing the error, millisecond; 529 529 * Lock – a flag to block the error until the device is restarted. 530 530 531 -The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. Error is removed when the power consumption is normal during “Delay before clearing the error” time.526 +The “Power fault” occurs when the device detects a shortage or high power consumption in mentioned power supplies. Error is removed when the power consumption is normal during “Delay before clearing the error” time. 532 532 533 533 (% class="box warningmessage" %) 534 534 ((( 535 -If there is the "Power fault", the **“Critical error” **is generated.530 +If there is the "Power switch error", the **“Critical error” **is generated. 536 536 ))) 537 537 538 538 === Charge contactor cycles === ... ... @@ -761,8 +761,6 @@ 761 761 762 762 === Critical error === 763 763 764 -Some of the errors are system critical. A separate signal named "Critical error" indicates a system misbehaviour. 765 - 766 766 To change the critical error parameters, select the "Protections → Critical error" section: 767 767 768 768 [[image:1733328487100-898.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]] ... ... @@ -774,10 +774,33 @@ 774 774 * Delay before clearing the error, second; 775 775 * Lock – a flag to block the error until the device is restarted. 776 776 777 -The "Critical error"flag is generated if at least one of thecritical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signalsanderrors.WebHome||anchor="HErrors"]])is generated during the “Delay before setting the error” time:770 +The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time: 778 778 779 -The “Critical error” flag is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 772 +* “Battery cover error”; 773 +* “Water”; 774 +* “Logic offline”; 775 +* “Cell count error”; 776 +* “ADC error”; 777 +* “Current sensor error”; 778 +* “Shunt offline”; 779 +* “Shunt error”; 780 +* “WDT reset” 781 +* “No temp. sensors”; 782 +* “Temperature sensor shorted”; 783 +* “Stuck contactor”; 784 +* “CH contactor feedback error”; 785 +* “DCH contactor feedback error”; 786 +* “Insulation fault”; 787 +* “PCH contactor feedback error”; 788 +* “CH/DCH contactor feedback error”; 789 +* “Main contactor feedback error”; 790 +* “High voltage fault”; 791 +* “Power switch error”; 792 +* “HVIL error”; 793 +* “Power fault”. 780 780 795 +The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 796 + 781 781 === General error === 782 782 783 783 To change the general error parameters, select the "Protections → Critical error" section: