Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -513,7 +513,7 @@ 513 513 514 514 (% class="box infomessage" %) 515 515 ((( 516 -**Note:** this error can be configured only under** 516 +**Note:** this error can be configured only under** "Service" account**. 517 517 ))) 518 518 519 519 To change the parameters of the power fault error, select the "Protections → Power fault" section: ... ... @@ -522,14 +522,16 @@ 522 522 523 523 In this section: 524 524 525 -* Delaybeforeclearingtheerror, second;525 +* Enable – a flag to enable the protection; 526 526 * Delay before setting the error, millisecond; 527 527 * Time to keep power off, millisecond; 528 528 * Delay before clearing the error, millisecond; 529 529 * Lock – a flag to block the error until the device is restarted. 530 530 531 -The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. Errorisremovedwhen thepowerconsumptionis normalduring“Delaybeforeclearingthe error”time.531 +The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. After that BMS turns off the corresponding power supply for the Time to keep power off 532 532 533 +Error is removed when the power consumption is normal during “Delay before clearing the error” time. 534 + 533 533 (% class="box warningmessage" %) 534 534 ((( 535 535 If there is the "Power fault", the **“Critical error” **is generated. ... ... @@ -761,6 +761,8 @@ 761 761 762 762 === Critical error === 763 763 766 +Some of the errors are system critical. A separate signal named "Critical error" indicates a system misbehaviour. 767 + 764 764 To change the critical error parameters, select the "Protections → Critical error" section: 765 765 766 766 [[image:1733328487100-898.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]] ... ... @@ -772,9 +772,9 @@ 772 772 * Delay before clearing the error, second; 773 773 * Lock – a flag to block the error until the device is restarted. 774 774 775 -The "Critical error" flag is generated if at least one of the critical errors (see [[Battery controllers: signals and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time:779 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time: 776 776 777 -The “Critical error ”flag is cleared if there are no errors from the list above during the “Delay before clearing the error” time.781 +The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 778 778 779 779 === General error === 780 780