... ... @@ -772,10 +772,33 @@
772 772  * Delay before clearing the error, second;
773 773  * Lock – a flag to block the error until the device is restarted.
774 774  
775 -The "Critical error" flag is generated if at least one of the critical errors (see [[Battery controllers: signals and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time:
775 +The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time:
776 776  
777 -The “Critical error” flag is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
777 +* “Battery cover error”;
778 +* “Water”;
779 +* “Logic offline”;
780 +* “Cell count error”;
781 +* “ADC error”;
782 +* “Current sensor error”;
783 +* “Shunt offline”;
784 +* “Shunt error”;
785 +* “WDT reset”
786 +* “No temp. sensors”;
787 +* “Temperature sensor shorted”;
788 +* “Stuck contactor”;
789 +* “CH contactor feedback error”;
790 +* “DCH contactor feedback error”;
791 +* “Insulation fault”;
792 +* “PCH contactor feedback error”;
793 +* “CH/DCH contactor feedback error”;
794 +* “Main contactor feedback error”;
795 +* “High voltage fault”;
796 +* “Power switch error”;
797 +* “HVIL error”;
798 +* “Power fault”.
778 778  
800 +The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
801 +
779 779  === General error ===
780 780  
781 781  To change the general error parameters, select the "Protections → Critical error" section: