Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -509,15 +509,8 @@ 509 509 510 510 === Power fault === 511 511 512 -BMS Main 3 device checks the status of CAN2,CAN3,RS-485-2andCurrentsensorspowersupply.512 +BMS Main 3 device checks the status of power supply o. To change the parameters of the power fault error, select the "Protections → Power fault" section: 513 513 514 -(% class="box infomessage" %) 515 -((( 516 -**Note:** this error can be configured only under** "Service" account**. 517 -))) 518 - 519 -To change the parameters of the power fault error, select the "Protections → Power fault" section: 520 - 521 521 [[image:1739284154410-676.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]] 522 522 523 523 In this section: ... ... @@ -528,11 +528,11 @@ 528 528 * Delay before clearing the error, millisecond; 529 529 * Lock – a flag to block the error until the device is restarted. 530 530 531 -The “Power fault” occurs when the device detects a shortage or highpower consumptioninpowersupplies mentionedabove. Error is removed when the powerconsumptionis normal during “Delay before clearing the error” time.524 +The “Power fault” occurs when the device detects a shortage in contactor coil control circuit or an overheating of the power switch. Error is removed when the temperature of power switch is normal during “Delay before clearing the error” time. 532 532 533 533 (% class="box warningmessage" %) 534 534 ((( 535 -If there is the "Power fault", the **“Critical error” **is generated.528 +If there is the "Power switch error", the **“Critical error” **is generated. 536 536 ))) 537 537 538 538 === Charge contactor cycles === ... ... @@ -772,10 +772,33 @@ 772 772 * Delay before clearing the error, second; 773 773 * Lock – a flag to block the error until the device is restarted. 774 774 775 -The "Critical error"flag is generated if at least one of thecritical errors (see [[Battery controllers: signals and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signalsanderrors.WebHome||anchor="HErrors"]])is generated during the “Delay before setting the error” time:768 +The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time: 776 776 777 -The “Critical error” flag is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 770 +* “Battery cover error”; 771 +* “Water”; 772 +* “Logic offline”; 773 +* “Cell count error”; 774 +* “ADC error”; 775 +* “Current sensor error”; 776 +* “Shunt offline”; 777 +* “Shunt error”; 778 +* “WDT reset” 779 +* “No temp. sensors”; 780 +* “Temperature sensor shorted”; 781 +* “Stuck contactor”; 782 +* “CH contactor feedback error”; 783 +* “DCH contactor feedback error”; 784 +* “Insulation fault”; 785 +* “PCH contactor feedback error”; 786 +* “CH/DCH contactor feedback error”; 787 +* “Main contactor feedback error”; 788 +* “High voltage fault”; 789 +* “Power switch error”; 790 +* “HVIL error”; 791 +* “Power fault”. 778 778 793 +The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 794 + 779 779 === General error === 780 780 781 781 To change the general error parameters, select the "Protections → Critical error" section: