... ... @@ -772,33 +772,10 @@
772 772  * Delay before clearing the error, second;
773 773  * Lock – a flag to block the error until the device is restarted.
774 774  
775 -The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time:
775 +The "Critical error" flag is generated if at least one of the critical errors (see [[Battery controllers: signals and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time:
776 776  
777 -* “Battery cover error”;
778 -* “Water”;
779 -* “Logic offline”;
780 -* “Cell count error”;
781 -* “ADC error”;
782 -* “Current sensor error”;
783 -* “Shunt offline”;
784 -* “Shunt error”;
785 -* “WDT reset”
786 -* “No temp. sensors”;
787 -* “Temperature sensor shorted”;
788 -* “Stuck contactor”;
789 -* “CH contactor feedback error”;
790 -* “DCH contactor feedback error”;
791 -* “Insulation fault”;
792 -* “PCH contactor feedback error”;
793 -* “CH/DCH contactor feedback error”;
794 -* “Main contactor feedback error”;
795 -* “High voltage fault”;
796 -* “Power switch error”;
797 -* “HVIL error”;
798 -* “Power fault”.
777 +The “Critical error” flag is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
799 799  
800 -The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
801 -
802 802  === General error ===
803 803  
804 804  To change the general error parameters, select the "Protections → Critical error" section: