Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -507,34 +507,6 @@ 507 507 If there is the "Power switch error", the **“Critical error” **is generated. 508 508 ))) 509 509 510 -=== Power fault === 511 - 512 -BMS Main 3 device checks the status of CAN2, CAN3, RS-485-2 and Current sensors power supply. 513 - 514 -(% class="box infomessage" %) 515 -((( 516 -**Note:** this error can be configured only under** "Service" account**. 517 -))) 518 - 519 -To change the parameters of the power fault error, select the "Protections → Power fault" section: 520 - 521 -[[image:1739284154410-676.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]] 522 - 523 -In this section: 524 - 525 -* Delay before clearing the error, second; 526 -* Delay before setting the error, millisecond; 527 -* Time to keep power off, millisecond; 528 -* Delay before clearing the error, millisecond; 529 -* Lock – a flag to block the error until the device is restarted. 530 - 531 -The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. Error is removed when the power consumption is normal during “Delay before clearing the error” time. 532 - 533 -(% class="box warningmessage" %) 534 -((( 535 -If there is the "Power fault", the **“Critical error” **is generated. 536 -))) 537 - 538 538 === Charge contactor cycles === 539 539 540 540 The BMS Main 3 device protects the charging contactor against frequent switching.