... ... @@ -507,34 +507,6 @@
507 507  If there is the "Power switch error", the **“Critical error” **is generated.
508 508  )))
509 509  
510 -=== Power fault ===
511 -
512 -BMS Main 3 device checks the status of CAN2, CAN3, RS-485-2 and Current sensors power supply.
513 -
514 -(% class="box infomessage" %)
515 -(((
516 -**Note:** this error can be configured only under** "Service" account**.
517 -)))
518 -
519 -To change the parameters of the power fault error, select the "Protections → Power fault" section:
520 -
521 -[[image:1739284154410-676.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]]
522 -
523 -In this section:
524 -
525 -* Delay before clearing the error, second;
526 -* Delay before setting the error, millisecond;
527 -* Time to keep power off, millisecond;
528 -* Delay before clearing the error, millisecond;
529 -* Lock – a flag to block the error until the device is restarted.
530 -
531 -The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. Error is removed when the power consumption is normal during “Delay before clearing the error” time.
532 -
533 -(% class="box warningmessage" %)
534 -(((
535 -If there is the "Power fault", the **“Critical error” **is generated.
536 -)))
537 -
538 538  === Charge contactor cycles ===