Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -511,6 +511,11 @@ 511 511 512 512 BMS Main 3 device checks the status of CAN2, CAN3, RS-485-2 and Current sensors power supply. 513 513 514 +(% class="box infomessage" %) 515 +((( 516 +**Note:** this error can be configured only under** "Service" account**. 517 +))) 518 + 514 514 To change the parameters of the power fault error, select the "Protections → Power fault" section: 515 515 516 516 [[image:1739284154410-676.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]] ... ... @@ -517,14 +517,16 @@ 517 517 518 518 In this section: 519 519 520 -* Delaybeforeclearingtheerror, second;525 +* Enable – a flag to enable the protection; 521 521 * Delay before setting the error, millisecond; 522 522 * Time to keep power off, millisecond; 523 523 * Delay before clearing the error, millisecond; 524 524 * Lock – a flag to block the error until the device is restarted. 525 525 526 -The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. Errorisremovedwhen thepowerconsumptionis normalduring“Delaybeforeclearingthe error”time.531 +The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. After that BMS turns off the corresponding power supply for the Time to keep power off 527 527 533 +Error is removed when the power consumption is normal during “Delay before clearing the error” time. 534 + 528 528 (% class="box warningmessage" %) 529 529 ((( 530 530 If there is the "Power fault", the **“Critical error” **is generated. ... ... @@ -756,6 +756,8 @@ 756 756 757 757 === Critical error === 758 758 766 +Some of the errors are system critical. A separate signal named "Critical error" indicates a system misbehaviour. 767 + 759 759 To change the critical error parameters, select the "Protections → Critical error" section: 760 760 761 761 [[image:1733328487100-898.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]] ... ... @@ -767,33 +767,10 @@ 767 767 * Delay before clearing the error, second; 768 768 * Lock – a flag to block the error until the device is restarted. 769 769 770 -The critical errorflag is generated if at least one of thefollowing errors is generated during the “Delay before setting the error” time:779 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time: 771 771 772 -* “Battery cover error”; 773 -* “Water”; 774 -* “Logic offline”; 775 -* “Cell count error”; 776 -* “ADC error”; 777 -* “Current sensor error”; 778 -* “Shunt offline”; 779 -* “Shunt error”; 780 -* “WDT reset” 781 -* “No temp. sensors”; 782 -* “Temperature sensor shorted”; 783 -* “Stuck contactor”; 784 -* “CH contactor feedback error”; 785 -* “DCH contactor feedback error”; 786 -* “Insulation fault”; 787 -* “PCH contactor feedback error”; 788 -* “CH/DCH contactor feedback error”; 789 -* “Main contactor feedback error”; 790 -* “High voltage fault”; 791 -* “Power switch error”; 792 -* “HVIL error”; 793 -* “Power fault”. 781 +The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 794 794 795 -The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 796 - 797 797 === General error === 798 798 799 799 To change the general error parameters, select the "Protections → Critical error" section: