Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -509,8 +509,15 @@ 509 509 510 510 === Power fault === 511 511 512 -BMS Main 3 device checks the status of power supply ofCAN2, CAN3, RS-485-2 and Current sensors. To change theparametersof the powerfault error,select the "Protections → Power fault" section:512 +BMS Main 3 device checks the status of CAN2, CAN3, RS-485-2 and Current sensors power supply. 513 513 514 +(% class="box infomessage" %) 515 +((( 516 +**Note:** this error can be configured only under** "Service" account**. 517 +))) 518 + 519 +To change the parameters of the power fault error, select the "Protections → Power fault" section: 520 + 514 514 [[image:1739284154410-676.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]] 515 515 516 516 In this section: ... ... @@ -521,11 +521,11 @@ 521 521 * Delay before clearing the error, millisecond; 522 522 * Lock – a flag to block the error until the device is restarted. 523 523 524 -The “Power fault” occurs when the device detects a shortage in contactorcoilcontrolcircuitr anoverheatingof thepower switch. Error is removed when thetemperatureof power switchis normal during “Delay before clearing the error” time.531 +The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. Error is removed when the power consumption is normal during “Delay before clearing the error” time. 525 525 526 526 (% class="box warningmessage" %) 527 527 ((( 528 -If there is the "Power switch error", the **“Critical error” **is generated.535 +If there is the "Power fault", the **“Critical error” **is generated. 529 529 ))) 530 530 531 531 === Charge contactor cycles === ... ... @@ -754,6 +754,8 @@ 754 754 755 755 === Critical error === 756 756 764 +Some of the errors are system critical. A separate signal named "Critical error" indicates a system misbehaviour. 765 + 757 757 To change the critical error parameters, select the "Protections → Critical error" section: 758 758 759 759 [[image:1733328487100-898.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]] ... ... @@ -765,33 +765,10 @@ 765 765 * Delay before clearing the error, second; 766 766 * Lock – a flag to block the error until the device is restarted. 767 767 768 -The critical error flag is generated if at least one of thefollowing errors is generated during the “Delay before setting the error” time:777 +The "Critical error" flag is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time: 769 769 770 -* “Battery cover error”; 771 -* “Water”; 772 -* “Logic offline”; 773 -* “Cell count error”; 774 -* “ADC error”; 775 -* “Current sensor error”; 776 -* “Shunt offline”; 777 -* “Shunt error”; 778 -* “WDT reset” 779 -* “No temp. sensors”; 780 -* “Temperature sensor shorted”; 781 -* “Stuck contactor”; 782 -* “CH contactor feedback error”; 783 -* “DCH contactor feedback error”; 784 -* “Insulation fault”; 785 -* “PCH contactor feedback error”; 786 -* “CH/DCH contactor feedback error”; 787 -* “Main contactor feedback error”; 788 -* “High voltage fault”; 789 -* “Power switch error”; 790 -* “HVIL error”; 791 -* “Power fault”. 779 +The “Critical error” flag is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 792 792 793 -The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 794 - 795 795 === General error === 796 796 797 797 To change the general error parameters, select the "Protections → Critical error" section: