Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -509,23 +509,32 @@ 509 509 510 510 === Power fault === 511 511 512 -BMS Main 3 device checks the status of power supply ofCAN2, CAN3.To changethe parameters of thepower fault error,selectthe "Protections → Powerfault" section:512 +BMS Main 3 device checks the status of CAN2, CAN3, RS-485-2 and Current sensors power supply. 513 513 514 +(% class="box infomessage" %) 515 +((( 516 +**Note:** this error can be configured only under** "Service" account**. 517 +))) 518 + 519 +To change the parameters of the power fault error, select the "Protections → Power fault" section: 520 + 514 514 [[image:1739284154410-676.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]] 515 515 516 516 In this section: 517 517 518 -* Delaybeforeclearingtheerror, second;525 +* Enable – a flag to enable the protection; 519 519 * Delay before setting the error, millisecond; 520 520 * Time to keep power off, millisecond; 521 521 * Delay before clearing the error, millisecond; 522 522 * Lock – a flag to block the error until the device is restarted. 523 523 524 -The “Power fault” occurs when the device detects a shortage i ncontactor coil controlcircuitor an overheatingof the power switch.Error is removedwhenthetemperatureofpowerswitchisnormalduring “Delaybefore clearingtheerror”time.531 +The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. After that BMS turns off the corresponding power supply for "Time to keep power off", then it tries to enable power again. 525 525 533 +Error is removed when the power consumption is normal during “Delay before clearing the error” time. 534 + 526 526 (% class="box warningmessage" %) 527 527 ((( 528 -If there is the "Power switch error", the **“Critical error” **is generated.537 +If there is the "Power fault", the **“Critical error” **is generated. 529 529 ))) 530 530 531 531 === Charge contactor cycles === ... ... @@ -745,8 +745,10 @@ 745 745 * Source is ON: Upper current limit, A; 746 746 * Lock – a flag to block the error until the device is restarted. 747 747 748 -If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored.757 +If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. 749 749 759 +Error clears if interlock loop is being restored. 760 + 750 750 (% class="box warningmessage" %) 751 751 ((( 752 752 If there is the “HVIL error”, the **“Critical error”** is generated. ... ... @@ -754,6 +754,8 @@ 754 754 755 755 === Critical error === 756 756 768 +Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault. 769 + 757 757 To change the critical error parameters, select the "Protections → Critical error" section: 758 758 759 759 [[image:1733328487100-898.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]] ... ... @@ -765,33 +765,10 @@ 765 765 * Delay before clearing the error, second; 766 766 * Lock – a flag to block the error until the device is restarted. 767 767 768 -The critical errorflag is generated if at least one of thefollowing errors is generated during the “Delay before setting the error” time:781 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time: 769 769 770 -* “Battery cover error”; 771 -* “Water”; 772 -* “Logic offline”; 773 -* “Cell count error”; 774 -* “ADC error”; 775 -* “Current sensor error”; 776 -* “Shunt offline”; 777 -* “Shunt error”; 778 -* “WDT reset” 779 -* “No temp. sensors”; 780 -* “Temperature sensor shorted”; 781 -* “Stuck contactor”; 782 -* “CH contactor feedback error”; 783 -* “DCH contactor feedback error”; 784 -* “Insulation fault”; 785 -* “PCH contactor feedback error”; 786 -* “CH/DCH contactor feedback error”; 787 -* “Main contactor feedback error”; 788 -* “High voltage fault”; 789 -* “Power switch error”; 790 -* “HVIL error”; 791 -* “Power fault”. 783 +The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 792 792 793 -The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 794 - 795 795 === General error === 796 796 797 797 To change the general error parameters, select the "Protections → Critical error" section: