Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -507,6 +507,27 @@ 507 507 If there is the "Power switch error", the **“Critical error” **is generated. 508 508 ))) 509 509 510 +=== Power fault === 511 + 512 +BMS Main 3 device checks the status of power supply o. To change the parameters of the power fault error, select the "Protections → Power fault" section: 513 + 514 +[[image:1739284154410-676.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]] 515 + 516 +In this section: 517 + 518 +* Delay before clearing the error, second; 519 +* Delay before setting the error, millisecond; 520 +* Time to keep power off, millisecond; 521 +* Delay before clearing the error, millisecond; 522 +* Lock – a flag to block the error until the device is restarted. 523 + 524 +The “Power fault” occurs when the device detects a shortage in contactor coil control circuit or an overheating of the power switch. Error is removed when the temperature of power switch is normal during “Delay before clearing the error” time. 525 + 526 +(% class="box warningmessage" %) 527 +((( 528 +If there is the "Power switch error", the **“Critical error” **is generated. 529 +))) 530 + 510 510 === Charge contactor cycles === 511 511 512 512 The BMS Main 3 device protects the charging contactor against frequent switching.