Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -507,6 +507,34 @@ 507 507 If there is the "Power switch error", the **“Critical error” **is generated. 508 508 ))) 509 509 510 +=== Power fault === 511 + 512 +BMS Main 3 device checks the status of CAN2, CAN3, RS-485-2 and Current sensors power supply. 513 + 514 +(% class="box infomessage" %) 515 +((( 516 +**Note:** this error can be configured only under** "Service" account**. 517 +))) 518 + 519 +To change the parameters of the power fault error, select the "Protections → Power fault" section: 520 + 521 +[[image:1739284154410-676.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]] 522 + 523 +In this section: 524 + 525 +* Delay before clearing the error, second; 526 +* Delay before setting the error, millisecond; 527 +* Time to keep power off, millisecond; 528 +* Delay before clearing the error, millisecond; 529 +* Lock – a flag to block the error until the device is restarted. 530 + 531 +The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. Error is removed when the power consumption is normal during “Delay before clearing the error” time. 532 + 533 +(% class="box warningmessage" %) 534 +((( 535 +If there is the "Power fault", the **“Critical error” **is generated. 536 +))) 537 + 510 510 === Charge contactor cycles === 511 511 512 512 The BMS Main 3 device protects the charging contactor against frequent switching. ... ... @@ -733,6 +733,8 @@ 733 733 734 734 === Critical error === 735 735 764 +Some of the errors are system critical. A separate signal named "Critical error" indicates a system misbehaviour. 765 + 736 736 To change the critical error parameters, select the "Protections → Critical error" section: 737 737 738 738 [[image:1733328487100-898.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]] ... ... @@ -744,33 +744,10 @@ 744 744 * Delay before clearing the error, second; 745 745 * Lock – a flag to block the error until the device is restarted. 746 746 747 -The critical error flag is generated if at least one of thefollowing errors is generated during the “Delay before setting the error” time:777 +The "Critical error" flag is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time: 748 748 749 -* “Battery cover error”; 750 -* “Water”; 751 -* “Logic offline”; 752 -* “Cell count error”; 753 -* “ADC error”; 754 -* “Current sensor error”; 755 -* “Shunt offline”; 756 -* “Shunt error”; 757 -* “WDT reset” 758 -* “No temp. sensors”; 759 -* “Temperature sensor shorted”; 760 -* “Stuck contactor”; 761 -* “CH contactor feedback error”; 762 -* “DCH contactor feedback error”; 763 -* “Insulation fault”; 764 -* “PCH contactor feedback error”; 765 -* “CH/DCH contactor feedback error”; 766 -* “Main contactor feedback error”; 767 -* “High voltage fault”; 768 -* “Power switch error”; 769 -* “HVIL error”; 770 -* “Power fault”. 779 +The “Critical error” flag is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 771 771 772 -The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 773 - 774 774 === General error === 775 775 776 776 To change the general error parameters, select the "Protections → Critical error" section:
- 1739284154410-676.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.4 KB - Content