Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,12 +6,6 @@ 6 6 7 7 The BMS Main 3 device continuously monitors the state of the cells, the external environment and, when detecting abnormalities, protects the battery and system components from damage. 8 8 9 -(% class="box warningmessage" %) 10 -((( 11 -**Attention!** 12 -Behavior of contactors at different errors is configured in **corresponding contactor settings**! 13 -))) 14 - 15 15 === Overcurrent === 16 16 17 17 The BMS Main 3 device performs the overcurrent protection depending on current sensor values. ... ... @@ -43,6 +43,11 @@ 43 43 * the current is positive (charging) or zero, and its modulo value is less than the “Tolerant charging current” value for the “Delay before clearing the error” time; 44 44 * the current is negative (discharging) or zero, and its modulo value is less than the “Tolerant discharging current” value for the “Delay before clearing the error” time. 45 45 40 +(% class="box infomessage" %) 41 +((( 42 +If there is the "Overcurrent" error, the **charging **and **discharging **contactors open. 43 +))) 44 + 46 46 === Charge current limit === 47 47 48 48 The BMS Main 3 device can check if the charging current exceeds the estimated limit based on the [[Charge map>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HChargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. ... ... @@ -54,13 +54,10 @@ 54 54 [[image:1735225207687-430.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="800"]]In this section: 55 55 56 56 * Enable – a flag to enable the protection; 57 -* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 58 -* Region 1: Current difference – a value of maximum absolute current diffr, A; 59 -* Region 2: Current difference – a value of maximum relative current excess, A; 60 -* Delay before setting the error, millisecond; 61 -* Delay before clearing the error, second; 62 -* Lock – a flag to block the error until the device is restarted. 56 +* Threshold to switch from Region 1 to Region 2 – a current value at which 57 +* 63 63 59 + 64 64 === Discharge current limit === 65 65 66 66 The BMS Main 3 device can check if the discharging current exceeds the estimated limit based on the [[Discharge map>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HDischargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. ... ... @@ -74,12 +74,7 @@ 74 74 In this section: 75 75 76 76 * Enable – a flag to enable the protection; 77 -* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 78 -* Region 1: Current difference – a value of maximum absolute current diffr, A; 79 -* Region 2: Current difference – a value of maximum relative current excess, A; 80 -* Delay before setting the error, millisecond; 81 -* Delay before clearing the error, second; 82 -* Lock – a flag to block the error until the device is restarted. 73 +* Threshold to switch from Region 1 to Region 2 83 83 84 84 === Undervoltage === 85 85 ... ... @@ -109,6 +109,11 @@ 109 109 110 110 * the minimum voltage among all cells of the battery is greater than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 111 111 103 +(% class="box infomessage" %) 104 +((( 105 +If there is the "Undervoltage" error, the **discharging **contactor opens. 106 +))) 107 + 112 112 === Overvoltage === 113 113 114 114 The BMS Main 3 device implements battery protection from too high voltage on the cells. ... ... @@ -137,6 +137,11 @@ 137 137 138 138 * the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 139 139 136 +(% class="box infomessage" %) 137 +((( 138 +If there is the "Overvoltage" error, the **charging** contactor and **discharging **contactor open (if the “Switch off the discharging contactor on error” flag is set). 139 +))) 140 + 140 140 === Low temperature === 141 141 142 142 The BMS Main 3 device implements battery protection from too low temperature. ... ... @@ -166,6 +166,12 @@ 166 166 167 167 * the minimum temperature among all cells of the battery is greater than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 168 168 170 +(% class="box infomessage" %) 171 +((( 172 +If there is the "Low temperature (CH)" error, the **charging **contactor opens. 173 +If there is the "Low temperature (DCH)" error, the **discharging **contactor opens. 174 +))) 175 + 169 169 === High temperature === 170 170 171 171 The BMS Main 3 device implements battery protection from too high temperature. ... ... @@ -195,6 +195,12 @@ 195 195 196 196 * the maximum temperature among all cells of the battery is less than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 197 197 205 +(% class="box infomessage" %) 206 +((( 207 +If there is the "High temperature (CH)" error, the **charging **contactor opens. 208 +If there is the "High temperature (DCH)" error, the **discharging **contactor opens. 209 +))) 210 + 198 198 === Battery cover === 199 199 200 200 To change the protection parameters from opening the battery cover, select the "Protections → Battery cover" section: ... ... @@ -220,7 +220,7 @@ 220 220 221 221 (% class="box warningmessage" %) 222 222 ((( 223 -If there is the "Battery cover error", the **“Critical error” **is generated**.** 236 +If there is the "Battery cover error", the **“Critical error” **is generated **and all contactors open.** 224 224 ))) 225 225 226 226 === High humidity === ... ... @@ -282,9 +282,9 @@ 282 282 283 283 * the measured humidity is less than the “Tolerant humidity” value during the “Delay before clearing the error” time. 284 284 285 -(% class="box warningmessage" %)298 +(% class="box infomessage" %) 286 286 ((( 287 -If there is the “Water” error, the **“Critical error”** is generated. 300 +If there is the “Water” error, the **“Critical error”** is generated and **all relays open**. 288 288 ))) 289 289 290 290 === Logic high temperature === ... ... @@ -340,7 +340,7 @@ 340 340 341 341 (% class="box warningmessage" %) 342 342 ((( 343 -If there is the "Logic offline" error, the **“Critical error” **is generated**.** 356 +If there is the "Logic offline" error, the **“Critical error” **is generated and **all relays open.** 344 344 ))) 345 345 346 346 === Cell count === ... ... @@ -369,7 +369,7 @@ 369 369 370 370 (% class="box warningmessage" %) 371 371 ((( 372 -If there is the "Cell count error", the **“Critical error” **is generated**.** 385 +If there is the "Cell count error", the **“Critical error” **is generated and **all relays open.** 373 373 ))) 374 374 375 375 === Logic count === ... ... @@ -397,7 +397,7 @@ 397 397 398 398 (% class="box warningmessage" %) 399 399 ((( 400 -If there is the "Logic count error", the **“Critical error”** is generated. 413 +If there is the "Logic count error", the **“Critical error”** is generated and **all relays open.** 401 401 ))) 402 402 403 403 === Short circuit === ... ... @@ -427,6 +427,11 @@ 427 427 428 428 * the current modulo is lower than the “Maximum current” values for all three protection levels during the “Delay before setting the error” time. 429 429 443 +(% class="box infomessage" %) 444 +((( 445 +If there is the "Short circuit" error, **charging **contactor opens (if the “Switch off the charging contactor on error” flag is set) and **discharging **contactor opens (if the “Switch off the discharging contactor on error flag” is set). 446 +))) 447 + 430 430 === High contactor temperature === 431 431 432 432 The BMS Main 3 device protects power contactors from overheating. To measure the temperature of the contactor, one of the thermistors connected to the X5 connector is used. ... ... @@ -455,6 +455,11 @@ 455 455 456 456 * the contactor temperature is lower than the “Tolerant contactor temperature” value during the “Delay before clearing the error” time. 457 457 476 +(% class="box infomessage" %) 477 +((( 478 +If there is the "High contactor temperature" error, **charging **contactor opens (if the “Switch off the charging contactor on error” flag is set) and **discharging **contactor opens (if the “Switch off the discharging contactor on error” flag is set). 479 +))) 480 + 458 458 === Current sensor === 459 459 460 460 The BMS Main 3 device checks the current sensor connection circuits. The circuits are checked for breakage and short-circuit to the +5 V supply line. ... ... @@ -486,7 +486,7 @@ 486 486 487 487 (% class="box warningmessage" %) 488 488 ((( 489 -If there is the “Current sensor error”, the **“Critical error” **is generated. 512 +If there is the “Current sensor error”, the **“Critical error” **is generated and **all relays open.** 490 490 ))) 491 491 492 492 === Power switch === ... ... @@ -504,9 +504,13 @@ 504 504 505 505 (% class="box warningmessage" %) 506 506 ((( 507 -If there is the "Power switch error", the **“Critical error” **is generated. 530 +If there is the "Power switch error", the **“Critical error” **is generated and **all relays open.** 508 508 ))) 509 509 533 +=== Power fault === 534 + 535 +TBA 536 + 510 510 === Charge contactor cycles === 511 511 512 512 The BMS Main 3 device protects the charging contactor against frequent switching. ... ... @@ -534,6 +534,11 @@ 534 534 535 535 * the “Delay before clearing the error” time has passed since the error was generated. 536 536 564 +(% class="box infomessage" %) 565 +((( 566 +If there is the "CH contactor cycles error" error, the **charging **contactor opens. 567 +))) 568 + 537 537 === Discharge contactor cycles === 538 538 539 539 The BMS Main 3 device protects the discharging contactor against frequent switching. ... ... @@ -561,6 +561,11 @@ 561 561 562 562 * the “Delay before clearing the error” time has passed since the error was generated. 563 563 596 +(% class="box infomessage" %) 597 +((( 598 +If there is the "DCH contactor cycles error" error, the **discharging **contactor opens. 599 +))) 600 + 564 564 === Temperature sensors === 565 565 566 566 The BMS Main 3 device checks the temperature sensors connection circuits. The circuits are checked for breakage and short-circuit. ... ... @@ -580,7 +580,7 @@ 580 580 581 581 (% class="box warningmessage" %) 582 582 ((( 583 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”** is generated. 620 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”** is generated and **all relays open.** 584 584 ))) 585 585 586 586 === WDT reset === ... ... @@ -603,7 +603,7 @@ 603 603 604 604 (% class="box warningmessage" %) 605 605 ((( 606 -If there is the "WDT reset" error, the **“Critical error” **is generated. 643 +If there is the "WDT reset" error, the **“Critical error” **is generated and **all relays open.** 607 607 ))) 608 608 609 609 === Unallowable charging === ... ... @@ -631,6 +631,11 @@ 631 631 632 632 * the battery current is zero during the “Delay before clearing the error” time. 633 633 671 +(% class="box infomessage" %) 672 +((( 673 +If there is the "Unallowable charging" error, the **discharging **contactor opens. 674 +))) 675 + 634 634 === Stuck contactor === 635 635 636 636 The BMS Main 3 device protects contactors against sticking. ... ... @@ -654,7 +654,7 @@ 654 654 655 655 (% class="box warningmessage" %) 656 656 ((( 657 -If there is the “Stuck contactor” error, the **“Critical error” **is generated. 699 +If there is the “Stuck contactor” error, the **“Critical error” **is generated and **all relays open.** 658 658 ))) 659 659 660 660 === Contactor feedback === ... ... @@ -678,7 +678,7 @@ 678 678 679 679 (% class="box warningmessage" %) 680 680 ((( 681 -If there is the “Contactor feedback” error, the **“Critical error” **is generated. 723 +If there is the “Contactor feedback” error, the **“Critical error” **is generated and **all relays open.** 682 682 ))) 683 683 684 684 === Insulation === ... ... @@ -704,7 +704,7 @@ 704 704 705 705 (% class="box warningmessage" %) 706 706 ((( 707 -If there is the “Insulation fault”, the **“Critical error”** is generated. 749 +If there is the “Insulation fault”, the **“Critical error”** is generated and **all relays open.** 708 708 ))) 709 709 710 710 === HVIL === ... ... @@ -728,7 +728,7 @@ 728 728 729 729 (% class="box warningmessage" %) 730 730 ((( 731 -If there is the “HVIL error”, the **“Critical error”** is generated. 773 +If there is the “HVIL error”, the **“Critical error”** is generated and **all relays open.** 732 732 ))) 733 733 734 734 === Critical error === ... ... @@ -766,11 +766,16 @@ 766 766 * “Main contactor feedback error”; 767 767 * “High voltage fault”; 768 768 * “Power switch error”; 769 -* “HVIL error” ;811 +* “HVIL error”l 770 770 * “Power fault”. 771 771 772 772 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 773 773 816 +(% class="box infomessage" %) 817 +((( 818 +If there is the “Critical error”, **all **contactors open. 819 +))) 820 + 774 774 === General error === 775 775 776 776 To change the general error parameters, select the "Protections → Critical error" section: ... ... @@ -791,5 +791,5 @@ 791 791 792 792 (% class="box infomessage" %) 793 793 ((( 794 -The state of the “General error” can be assignedto a discrete output ortoa power switch.841 +The state of the “General error” can be output to a discrete output or a power switch. 795 795 )))