Изменения документа 3.4 Protections
Редактировал(а) Admin 2025/04/09 12:21
Сводка
-
Свойства страницы (1 изменено, 0 добавлено, 0 удалено)
Подробности
- Свойства страницы
-
- Содержимое
-
... ... @@ -43,7 +43,7 @@ 43 43 44 44 === Charge current limit === 45 45 46 - УстройствоBMS Main 3можетпроверятьпревышениетоказарядаисравнивать46 +The BMS Main 3 device can check if the charging current exceeds the estimated limit based on the [[Charge map>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HChargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. 47 47 48 48 Current difference is separated to two regions by the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference. 49 49 ... ... @@ -81,59 +81,59 @@ 81 81 82 82 === Undervoltage === 83 83 84 - ВустройствеBMS Main 3реализованазащитабатареиотнизкогонапряжениянаячейках.84 +The BMS Main 3 device implements battery protection from too low voltage on the cells. 85 85 86 - Дляизмененияпараметровзащитыбатареипринизкомнапряжениинаячейкахнеобходимовыбратьраздел«Protections → Undervoltage»:86 +To change the battery protection parameters from low voltage on the cells, select the "Protections → Undervoltage" section: 87 87 88 88 [[image:1735224224155-829.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]] 89 89 90 - Вданномразделе:90 +In this section: 91 91 92 -* Enable – флагвключениязащиты;93 -* Minimum cell voltage – минимальное напряжение на ячейке,В;94 -* Tolerant cell voltage – допустимое напряжение на ячейке,В;95 -* Check the open circuit voltage instead of the actual voltage – флагвключениякоррекциинапряжениепотокуисопротивлениюячейки;96 -* Delay before setting the error – задержка перед формированием ошибки,мс;97 -* Delay before clearing the error – задержка перед снятием ошибки,с;98 -* Lock – флагблокированияошибкидоперезапускаустройства.92 +* Enable – a flag to enable the protection; 93 +* Minimum cell voltage, V; 94 +* Tolerant cell voltage, V; 95 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 96 +* Delay before setting the error, millisecond; 97 +* Delay before clearing the error, second; 98 +* Lock – a flag to block the error until the device is restarted. 99 99 100 - Врезультатесрабатываниязащитыбатареиотнизкогонапряжениеформируетсяошибка«Undervoltage».100 +As a result of the operation of battery protection from low voltage, the "Undervoltage" error is generated. 101 101 102 - Условияформированияошибки:102 +Error generation conditions: 103 103 104 -* минимальноенапряжениесредивсехячеекбатареименьшевеличины«Minimum cell voltage»втечениевремени«Delay before setting the error».104 +* the minimum voltage among all cells of the battery is less than the “Minimum cell voltage” value for the “Delay before setting the error” time. 105 105 106 - Условияснятияошибки:106 +Conditions for removing the error: 107 107 108 -* минимальноенапряжениесредивсехячеекбатареибольшевеличины«Tolerant cell voltage»втечениевремени«Delay before clearing the error».108 +* the minimum voltage among all cells of the battery is greater than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 109 109 110 110 === Overvoltage === 111 111 112 - ВустройствеBMS Main 3реализованазащитабатареиотвысокогонапряжениянаячейках.112 +The BMS Main 3 device implements battery protection from too high voltage on the cells. 113 113 114 - Дляизмененияпараметровзащитыбатареипривысокомнапряжениинаячейкахнеобходимовыбратьраздел«Protections → Overvoltage»:114 +To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section: 115 115 116 116 [[image:1735224377252-473.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]] 117 117 118 - Вданномразделе:118 +In this section: 119 119 120 -* Enable – флагвключениязащиты;121 -* Maximum cell voltage – максимальное напряжение на ячейке,В;122 -* Tolerant cell voltage – допустимое напряжение на ячейке,В;123 -* Check the open circuit voltage instead of the actual voltage – флагвключениякоррекциинапряжениепотокуисопротивлениюячейки;124 -* Delay before setting the error – задержка перед формированием ошибки,мс;125 -* Delay before clearing the error – задержка перед снятием ошибки,с;126 -* Lock – флагблокированияошибкидоперезапускаустройства.120 +* Enable – a flag to enable the protection; 121 +* Maximum cell voltage, V; 122 +* Tolerant cell voltage, V; 123 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 124 +* Delay before setting the error, millisecond; 125 +* Delay before clearing the error, second; 126 +* Lock – a flag to block the error until the device is restarted. 127 127 128 - Врезультатесрабатываниязащитыбатареиотвысокогонапряжениеформируетсяошибка«Overvoltage».128 +As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. 129 129 130 - Условияформированияошибки:130 +Error generation conditions: 131 131 132 -* максимальноенапряжениесредивсехячеекбатареибольшевеличины«Maximum cell voltage»втечениевремени«Delay before setting the error».132 +* the maximum voltage among all cells of the battery is greater than the “Maximum cell voltage” value for the “Delay before setting the error” time. 133 133 134 - Условияснятияошибки:134 +Conditions for removing the error: 135 135 136 -* максимальное напряжениесредивсехячеекбатареименьшевеличины«Tolerant cell voltage»втечениевремени«Delay before clearing the error».136 +* the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 137 137 138 138 === Low temperature === 139 139