Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.bms-main-3.3\.Settings.WebHome1 +Battery management systems.BMS Main 3.3\. Configuration.WebHome - Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= SettingsThe BMS Main 3 device continuously monitors the state ofthe cells, the external environment and, when detectingabnormalities, protects the battery and system components from damage.The BMS Main 3 device continuously monitors the state of the cells, the external environmentand, when detecting abnormalities, protects the battery and system components from damage.=2 += Configuration = 3 3 4 4 (% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == Protections == ... ... @@ -42,6 +42,14 @@ 42 42 If there is the "Overcurrent" error, the **charging **and **discharging **contactors open. 43 43 ))) 44 44 45 +=== Charge current limit === 46 + 47 +TBA 48 + 49 +=== Discharge current limit === 50 + 51 +TBA 52 + 45 45 === Undervoltage === 46 46 47 47 The BMS Main 3 device implements battery protection from too low voltage on the cells. ... ... @@ -269,7 +269,7 @@ 269 269 If there is the “Water” error, the **“Critical error”** is generated and **all relays open**. 270 270 ))) 271 271 272 -=== HighLogic temperature ===280 +=== Logic high temperature === 273 273 274 274 To change the overheating protection parameters of BMS Logic devices, select the "Protections → High Logic temperature" section: 275 275 ... ... @@ -294,9 +294,9 @@ 294 294 295 295 * a BMS Logic device temperature is less than the “Tolerant temperature” value. 296 296 297 -(% class="box warningmessage" %)305 +(% class="box infomessage" %) 298 298 ((( 299 - Overheated Logic devicesdo notbalancecells.307 +Cell balancing is disabled on Logic devices with high temperature. 300 300 ))) 301 301 302 302 === Logic offline === ... ... @@ -503,6 +503,10 @@ 503 503 If there is the "Power switch error", the **“Critical error” **is generated and **all relays open.** 504 504 ))) 505 505 514 +=== Power fault === 515 + 516 +TBA 517 + 506 506 === Charge contactor cycles === 507 507 508 508 The BMS Main 3 device protects the charging contactor against frequent switching. ... ... @@ -535,7 +535,7 @@ 535 535 If there is the "CH contactor cycles error" error, the **charging **contactor opens. 536 536 ))) 537 537 538 -=== Discharge contactor cycles ===550 +=== Discharge contactor cycles === 539 539 540 540 The BMS Main 3 device protects the discharging contactor against frequent switching. 541 541 ... ... @@ -586,7 +586,7 @@ 586 586 587 587 (% class="box warningmessage" %) 588 588 ((( 589 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”** is generated and **all relays open.** 601 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”** is generated and **all relays open.** 590 590 ))) 591 591 592 592 === WDT reset === ... ... @@ -612,7 +612,7 @@ 612 612 If there is the "WDT reset" error, the **“Critical error” **is generated and **all relays open.** 613 613 ))) 614 614 615 -=== Unallowable charging ===627 +=== Unallowable charging === 616 616 617 617 The BMS can detect that the battery is charging through the discharging circuit and protectively open the discharging contactor to prevent unallowable battery operation. 618 618 ... ... @@ -642,7 +642,7 @@ 642 642 If there is the "Unallowable charging" error, the **discharging **contactor opens. 643 643 ))) 644 644 645 -=== Stuck contactor ===657 +=== Stuck contactor === 646 646 647 647 The BMS Main 3 device protects contactors against sticking. 648 648 ... ... @@ -692,30 +692,8 @@ 692 692 If there is the “Contactor feedback” error, the **“Critical error” **is generated and **all relays open.** 693 693 ))) 694 694 695 -=== Precharge===707 +=== Insulation === 696 696 697 -BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors. To change the pre-charge monitoring parameters, select the "Protections → Precharge" section: 698 - 699 -[[image:1733328487097-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="99" width="800"]] 700 - 701 -In this section: 702 - 703 -* Enable – a flag to enable the protection; 704 -* Delay before setting the error, millisecond; 705 -* Delay before clearing the error, second; 706 -* Lock – a flag to block the error until the device is restarted. 707 - 708 -As a result of the protection algorithms the “Precharge error” is generated. Error generation conditions: 709 - 710 -* precharging process cannot be finished (the precharge current does not decrease or voltages before and after contactors are not equal) during the “Delay before setting the error” time. 711 - 712 -(% class="box infomessage" %) 713 -((( 714 -If there is the “Precharge error”, **charging **and **discharging **contactors open. 715 -))) 716 - 717 -=== Insulation === 718 - 719 719 The BMS Main 3 device can detect a physical signal or CAN bus message from an external insulation monitoring device (such as Bender IR155, iso165C, BMD IMD) to monitor the insulation quality. 720 720 721 721 To change the insulation monitoring parameters, select the "Protections → Insulation" section: ... ... @@ -805,7 +805,7 @@ 805 805 If there is the “Critical error”, **all **contactors open. 806 806 ))) 807 807 808 -=== General error ===798 +=== General error === 809 809 810 810 To change the general error parameters, select the "Protections → Critical error" section: 811 811