Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.bms-main-3.3\.Settings.WebHome1 +Battery management systems.BMS Main 3.3\. Configuration.WebHome - Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Settings TheBMS Main 3 device continuously monitors the state of the cells, the external environment and, when detecting abnormalities, protects the battery and system components from damage.The BMS Main 3 device continuously monitors the state of the cells, the external environment and, when detecting abnormalities, protects the battery and system components from damage.=2 += Settings = 3 3 4 4 (% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == Protections == ... ... @@ -294,9 +294,9 @@ 294 294 295 295 * a BMS Logic device temperature is less than the “Tolerant temperature” value. 296 296 297 -(% class="box warningmessage" %)297 +(% class="box infomessage" %) 298 298 ((( 299 - Overheated Logic devicesdo notbalancecells.299 +Cell balancing is disabled on Logic devices with high temperature. 300 300 ))) 301 301 302 302 === Logic offline === ... ... @@ -535,7 +535,7 @@ 535 535 If there is the "CH contactor cycles error" error, the **charging **contactor opens. 536 536 ))) 537 537 538 -=== Discharge contactor cycles ===538 +=== Discharge contactor cycles === 539 539 540 540 The BMS Main 3 device protects the discharging contactor against frequent switching. 541 541 ... ... @@ -586,7 +586,7 @@ 586 586 587 587 (% class="box warningmessage" %) 588 588 ((( 589 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”** is generated and **all relays open.** 589 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”** is generated and **all relays open.** 590 590 ))) 591 591 592 592 === WDT reset === ... ... @@ -612,7 +612,7 @@ 612 612 If there is the "WDT reset" error, the **“Critical error” **is generated and **all relays open.** 613 613 ))) 614 614 615 -=== Unallowable charging ===615 +=== Unallowable charging === 616 616 617 617 The BMS can detect that the battery is charging through the discharging circuit and protectively open the discharging contactor to prevent unallowable battery operation. 618 618