Changes for page 3.4 Protections

Last modified by Admin on 2025/04/09 12:19

From version 16.8
edited by Admin
on 2024/12/26 15:03
Change comment: There is no comment for this version
To version 13.2
edited by Admin
on 2024/12/26 14:55
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -44,16 +44,8 @@
44 44  
45 45  === Charge current limit ===
46 46  
47 -The BMS Main 3 device can check the charging current with the limit based on the Charge map. If current is more than estimated maximum, "Current limit" error is generated.
47 +TBA
48 48  
49 -To change the overcurrent protection of the battery, select the "Protections → Charge current limit" section:
50 -
51 -[[image:1735225207687-430.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="800"]]In this section:
52 -
53 -* Enable – a flag to enable the protection;
54 -* The
55 -
56 -
57 57  === Discharge current limit ===
58 58  
59 59  TBA
... ... @@ -752,7 +752,7 @@
752 752  * Source is ON: Upper current limit, A;
753 753  * Lock – a flag to block the error until the device is restarted.
754 754  
755 -If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored.
747 +If interlock loop breaks and its curre, the “HVIL error” is generated. Error clears if interlock loop is being restored.
756 756  
757 757  (% class="box warningmessage" %)
758 758  (((
... ... @@ -808,7 +808,7 @@
808 808  
809 809  To change the general error parameters, select the "Protections → Critical error" section:
810 810  
811 -[[image:1735224942262-497.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
803 +[[image:1733328487101-216.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]]
812 812  
813 813  In this section:
814 814  
... ... @@ -816,7 +816,7 @@
816 816  * Delay before setting the error, millisecond;
817 817  * Delay before clearing the error, second;
818 818  * Lock – a flag to block the error until the device is restarted;
819 -* Errors 1, 2 to set the "Critical errorbitfields to enable check of corresponding errors.
811 +* Check: <error> a flags to enable check of corresponding errors.
820 820  
821 821  The general error flag is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time.
822 822  
1735224942262-497.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -19.9 KB
Content
1735225207687-430.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -23.0 KB
Content