Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -44,9 +44,9 @@ 44 44 45 45 === Charge current limit === 46 46 47 -The BMS Main 3 device can check if the charging current exceeds the estimated limit based on the [[Charge map>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HChargemap"]]. 47 +The BMS Main 3 device can check if the charging current exceeds the estimated limit based on the [[Charge map>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HChargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. 48 48 49 -Current difference is configuredbytwo regionsseparatedby the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference.49 +Current difference is separated to two regions by the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference. 50 50 51 51 To change the overcurrent protection of the battery, select the "Protections → Charge current limit" section: 52 52 ... ... @@ -53,18 +53,25 @@ 53 53 [[image:1735225207687-430.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="800"]]In this section: 54 54 55 55 * Enable – a flag to enable the protection; 56 -* Threshold to switch from Region 1 to Region 2 56 +* Threshold to switch from Region 1 to Region 2 – a current value at which 57 57 * 58 58 59 59 60 60 === Discharge current limit === 61 61 62 -The BMS Main 3 device can check if the charging current exceeds the estimated limit based on the [[Discharge map>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HDischargemap"]]. 62 +The BMS Main 3 device can check if the discharging current exceeds the estimated limit based on the [[Discharge map>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HDischargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. 63 63 64 -Current difference is configuredbytwo regionsseparatedby the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference.64 +Current difference is separated to two regions by the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference. 65 65 66 -To change the overcurrent protection of the battery, select the "Protections → Charge current limit" section:66 +To change the overcurrent protection of the battery, select the "Protections → Discharge current limit" section: 67 67 68 +[[image:1735225942893-869.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="800"]] 69 + 70 +In this section: 71 + 72 +* Enable – a flag to enable the protection; 73 +* Threshold to switch from Region 1 to Region 2 74 + 68 68 === Undervoltage === 69 69 70 70 The BMS Main 3 device implements battery protection from too low voltage on the cells.
- 1735225942893-869.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.1 KB - Content