- Page properties
-
- Content
-
... ... @@ -6,6 +6,12 @@ 6 6 7 7 The BMS Main 3 device continuously monitors the state of the cells, the external environment and, when detecting abnormalities, protects the battery and system components from damage. 8 8 9 +(% class="box errormessage" %) 10 +((( 11 +**Attention!** 12 +Behavior of contactors at different errors is configured in **corresponding contactor settings**! 13 +))) 14 + 9 9 === Overcurrent === 10 10 11 11 The BMS Main 3 device performs the overcurrent protection depending on current sensor values. ... ... @@ -37,16 +37,11 @@ 37 37 * the current is positive (charging) or zero, and its modulo value is less than the “Tolerant charging current” value for the “Delay before clearing the error” time; 38 38 * the current is negative (discharging) or zero, and its modulo value is less than the “Tolerant discharging current” value for the “Delay before clearing the error” time. 39 39 40 -(% class="box infomessage" %) 41 -((( 42 -If there is the "Overcurrent" error, the **charging **and **discharging **contactors open. 43 -))) 44 - 45 45 === Charge current limit === 46 46 47 -The BMS Main 3 device can check if the charging current exceeds the estimated limit based on the [[Charge map>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HChargemap"]]. 48 +The BMS Main 3 device can check if the charging current exceeds the estimated limit based on the [[Charge map>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HChargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. 48 48 49 -Current difference is configuredbytwo regionsseparatedby the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference.50 +Current difference is separated to two regions by the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference. 50 50 51 51 To change the overcurrent protection of the battery, select the "Protections → Charge current limit" section: 52 52 ... ... @@ -53,14 +53,33 @@ 53 53 [[image:1735225207687-430.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="800"]]In this section: 54 54 55 55 * Enable – a flag to enable the protection; 56 -* Threshold to switch from Region 1 to Region 2 57 -* 57 +* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 58 +* Region 1: Current difference – a value of maximum absolute current diffr, A; 59 +* Region 2: Current difference – a value of maximum relative current excess, A; 60 +* Delay before setting the error, millisecond; 61 +* Delay before clearing the error, second; 62 +* Lock – a flag to block the error until the device is restarted. 58 58 59 - 60 60 === Discharge current limit === 61 61 62 -TB A66 +The BMS Main 3 device can check if the discharging current exceeds the estimated limit based on the [[Discharge map>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HDischargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. 63 63 68 +Current difference is separated to two regions by the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference. 69 + 70 +To change the overcurrent protection of the battery, select the "Protections → Discharge current limit" section: 71 + 72 +[[image:1735225942893-869.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="800"]] 73 + 74 +In this section: 75 + 76 +* Enable – a flag to enable the protection; 77 +* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 78 +* Region 1: Current difference – a value of maximum absolute current diffr, A; 79 +* Region 2: Current difference – a value of maximum relative current excess, A; 80 +* Delay before setting the error, millisecond; 81 +* Delay before clearing the error, second; 82 +* Lock – a flag to block the error until the device is restarted. 83 + 64 64 === Undervoltage === 65 65 66 66 The BMS Main 3 device implements battery protection from too low voltage on the cells. ... ... @@ -89,11 +89,6 @@ 89 89 90 90 * the minimum voltage among all cells of the battery is greater than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 91 91 92 -(% class="box infomessage" %) 93 -((( 94 -If there is the "Undervoltage" error, the **discharging **contactor opens. 95 -))) 96 - 97 97 === Overvoltage === 98 98 99 99 The BMS Main 3 device implements battery protection from too high voltage on the cells. ... ... @@ -122,11 +122,6 @@ 122 122 123 123 * the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 124 124 125 -(% class="box infomessage" %) 126 -((( 127 -If there is the "Overvoltage" error, the **charging** contactor and **discharging **contactor open (if the “Switch off the discharging contactor on error” flag is set). 128 -))) 129 - 130 130 === Low temperature === 131 131 132 132 The BMS Main 3 device implements battery protection from too low temperature. ... ... @@ -156,12 +156,6 @@ 156 156 157 157 * the minimum temperature among all cells of the battery is greater than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 158 158 159 -(% class="box infomessage" %) 160 -((( 161 -If there is the "Low temperature (CH)" error, the **charging **contactor opens. 162 -If there is the "Low temperature (DCH)" error, the **discharging **contactor opens. 163 -))) 164 - 165 165 === High temperature === 166 166 167 167 The BMS Main 3 device implements battery protection from too high temperature. ... ... @@ -191,12 +191,6 @@ 191 191 192 192 * the maximum temperature among all cells of the battery is less than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 193 193 194 -(% class="box infomessage" %) 195 -((( 196 -If there is the "High temperature (CH)" error, the **charging **contactor opens. 197 -If there is the "High temperature (DCH)" error, the **discharging **contactor opens. 198 -))) 199 - 200 200 === Battery cover === 201 201 202 202 To change the protection parameters from opening the battery cover, select the "Protections → Battery cover" section: ... ... @@ -222,7 +222,7 @@ 222 222 223 223 (% class="box warningmessage" %) 224 224 ((( 225 -If there is the "Battery cover error", the **“Critical error” **is generated and all contactors open.**223 +If there is the "Battery cover error", the **“Critical error” **is generated**.** 226 226 ))) 227 227 228 228 === High humidity === ... ... @@ -284,9 +284,9 @@ 284 284 285 285 * the measured humidity is less than the “Tolerant humidity” value during the “Delay before clearing the error” time. 286 286 287 -(% class="box in fomessage" %)285 +(% class="box warningmessage" %) 288 288 ((( 289 -If there is the “Water” error, the **“Critical error”** is generated and **all relays open**.287 +If there is the “Water” error, the **“Critical error”** is generated. 290 290 ))) 291 291 292 292 === Logic high temperature === ... ... @@ -342,7 +342,7 @@ 342 342 343 343 (% class="box warningmessage" %) 344 344 ((( 345 -If there is the "Logic offline" error, the **“Critical error” **is generated and**all relays open.**343 +If there is the "Logic offline" error, the **“Critical error” **is generated**.** 346 346 ))) 347 347 348 348 === Cell count === ... ... @@ -371,7 +371,7 @@ 371 371 372 372 (% class="box warningmessage" %) 373 373 ((( 374 -If there is the "Cell count error", the **“Critical error” **is generated and**all relays open.**372 +If there is the "Cell count error", the **“Critical error” **is generated**.** 375 375 ))) 376 376 377 377 === Logic count === ... ... @@ -399,7 +399,7 @@ 399 399 400 400 (% class="box warningmessage" %) 401 401 ((( 402 -If there is the "Logic count error", the **“Critical error”** is generated and **all relays open.**400 +If there is the "Logic count error", the **“Critical error”** is generated. 403 403 ))) 404 404 405 405 === Short circuit === ... ... @@ -429,11 +429,6 @@ 429 429 430 430 * the current modulo is lower than the “Maximum current” values for all three protection levels during the “Delay before setting the error” time. 431 431 432 -(% class="box infomessage" %) 433 -((( 434 -If there is the "Short circuit" error, **charging **contactor opens (if the “Switch off the charging contactor on error” flag is set) and **discharging **contactor opens (if the “Switch off the discharging contactor on error flag” is set). 435 -))) 436 - 437 437 === High contactor temperature === 438 438 439 439 The BMS Main 3 device protects power contactors from overheating. To measure the temperature of the contactor, one of the thermistors connected to the X5 connector is used. ... ... @@ -462,11 +462,6 @@ 462 462 463 463 * the contactor temperature is lower than the “Tolerant contactor temperature” value during the “Delay before clearing the error” time. 464 464 465 -(% class="box infomessage" %) 466 -((( 467 -If there is the "High contactor temperature" error, **charging **contactor opens (if the “Switch off the charging contactor on error” flag is set) and **discharging **contactor opens (if the “Switch off the discharging contactor on error” flag is set). 468 -))) 469 - 470 470 === Current sensor === 471 471 472 472 The BMS Main 3 device checks the current sensor connection circuits. The circuits are checked for breakage and short-circuit to the +5 V supply line. ... ... @@ -498,7 +498,7 @@ 498 498 499 499 (% class="box warningmessage" %) 500 500 ((( 501 -If there is the “Current sensor error”, the **“Critical error” **is generated and **all relays open.**489 +If there is the “Current sensor error”, the **“Critical error” **is generated. 502 502 ))) 503 503 504 504 === Power switch === ... ... @@ -516,13 +516,37 @@ 516 516 517 517 (% class="box warningmessage" %) 518 518 ((( 519 -If there is the "Power switch error", the **“Critical error” **is generated and **all relays open.**507 +If there is the "Power switch error", the **“Critical error” **is generated. 520 520 ))) 521 521 522 522 === Power fault === 523 523 524 - TBA512 +BMS Main 3 device checks the status of CAN2, CAN3, RS-485-2 and Current sensors power supply. 525 525 514 +(% class="box infomessage" %) 515 +((( 516 +**Note:** this error can be configured only under** "Service" account**. 517 +))) 518 + 519 +To change the parameters of the power fault error, select the "Protections → Power fault" section: 520 + 521 +[[image:1739284154410-676.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="96" width="800"]] 522 + 523 +In this section: 524 + 525 +* Delay before clearing the error, second; 526 +* Delay before setting the error, millisecond; 527 +* Time to keep power off, millisecond; 528 +* Delay before clearing the error, millisecond; 529 +* Lock – a flag to block the error until the device is restarted. 530 + 531 +The “Power fault” occurs when the device detects a shortage or high power consumption in power supplies mentioned above. Error is removed when the power consumption is normal during “Delay before clearing the error” time. 532 + 533 +(% class="box warningmessage" %) 534 +((( 535 +If there is the "Power fault", the **“Critical error” **is generated. 536 +))) 537 + 526 526 === Charge contactor cycles === 527 527 528 528 The BMS Main 3 device protects the charging contactor against frequent switching. ... ... @@ -550,11 +550,6 @@ 550 550 551 551 * the “Delay before clearing the error” time has passed since the error was generated. 552 552 553 -(% class="box infomessage" %) 554 -((( 555 -If there is the "CH contactor cycles error" error, the **charging **contactor opens. 556 -))) 557 - 558 558 === Discharge contactor cycles === 559 559 560 560 The BMS Main 3 device protects the discharging contactor against frequent switching. ... ... @@ -582,11 +582,6 @@ 582 582 583 583 * the “Delay before clearing the error” time has passed since the error was generated. 584 584 585 -(% class="box infomessage" %) 586 -((( 587 -If there is the "DCH contactor cycles error" error, the **discharging **contactor opens. 588 -))) 589 - 590 590 === Temperature sensors === 591 591 592 592 The BMS Main 3 device checks the temperature sensors connection circuits. The circuits are checked for breakage and short-circuit. ... ... @@ -606,7 +606,7 @@ 606 606 607 607 (% class="box warningmessage" %) 608 608 ((( 609 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”** is generated and **all relays open.**611 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”** is generated. 610 610 ))) 611 611 612 612 === WDT reset === ... ... @@ -629,7 +629,7 @@ 629 629 630 630 (% class="box warningmessage" %) 631 631 ((( 632 -If there is the "WDT reset" error, the **“Critical error” **is generated and **all relays open.**634 +If there is the "WDT reset" error, the **“Critical error” **is generated. 633 633 ))) 634 634 635 635 === Unallowable charging === ... ... @@ -657,11 +657,6 @@ 657 657 658 658 * the battery current is zero during the “Delay before clearing the error” time. 659 659 660 -(% class="box infomessage" %) 661 -((( 662 -If there is the "Unallowable charging" error, the **discharging **contactor opens. 663 -))) 664 - 665 665 === Stuck contactor === 666 666 667 667 The BMS Main 3 device protects contactors against sticking. ... ... @@ -685,7 +685,7 @@ 685 685 686 686 (% class="box warningmessage" %) 687 687 ((( 688 -If there is the “Stuck contactor” error, the **“Critical error” **is generated and **all relays open.**685 +If there is the “Stuck contactor” error, the **“Critical error” **is generated. 689 689 ))) 690 690 691 691 === Contactor feedback === ... ... @@ -709,7 +709,7 @@ 709 709 710 710 (% class="box warningmessage" %) 711 711 ((( 712 -If there is the “Contactor feedback” error, the **“Critical error” **is generated and **all relays open.**709 +If there is the “Contactor feedback” error, the **“Critical error” **is generated. 713 713 ))) 714 714 715 715 === Insulation === ... ... @@ -735,7 +735,7 @@ 735 735 736 736 (% class="box warningmessage" %) 737 737 ((( 738 -If there is the “Insulation fault”, the **“Critical error”** is generated and **all relays open.**735 +If there is the “Insulation fault”, the **“Critical error”** is generated. 739 739 ))) 740 740 741 741 === HVIL === ... ... @@ -759,7 +759,7 @@ 759 759 760 760 (% class="box warningmessage" %) 761 761 ((( 762 -If there is the “HVIL error”, the **“Critical error”** is generated and **all relays open.**759 +If there is the “HVIL error”, the **“Critical error”** is generated. 763 763 ))) 764 764 765 765 === Critical error === ... ... @@ -775,38 +775,10 @@ 775 775 * Delay before clearing the error, second; 776 776 * Lock – a flag to block the error until the device is restarted. 777 777 778 -The critical error flag is generated if at least one of thefollowing errors is generated during the “Delay before setting the error” time:775 +The "Critical error" flag is generated if at least one of the critical errors (see [[Battery controllers: signals and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time: 779 779 780 -* “Battery cover error”; 781 -* “Water”; 782 -* “Logic offline”; 783 -* “Cell count error”; 784 -* “ADC error”; 785 -* “Current sensor error”; 786 -* “Shunt offline”; 787 -* “Shunt error”; 788 -* “WDT reset” 789 -* “No temp. sensors”; 790 -* “Temperature sensor shorted”; 791 -* “Stuck contactor”; 792 -* “CH contactor feedback error”; 793 -* “DCH contactor feedback error”; 794 -* “Insulation fault”; 795 -* “PCH contactor feedback error”; 796 -* “CH/DCH contactor feedback error”; 797 -* “Main contactor feedback error”; 798 -* “High voltage fault”; 799 -* “Power switch error”; 800 -* “HVIL error”l 801 -* “Power fault”. 777 +The “Critical error” flag is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 802 802 803 -The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 804 - 805 -(% class="box infomessage" %) 806 -((( 807 -If there is the “Critical error”, **all **contactors open. 808 -))) 809 - 810 810 === General error === 811 811 812 812 To change the general error parameters, select the "Protections → Critical error" section: ... ... @@ -827,5 +827,5 @@ 827 827 828 828 (% class="box infomessage" %) 829 829 ((( 830 -The state of the “General error” can be outputto a discrete output or a power switch.799 +The state of the “General error” can be assigned to a discrete output or to a power switch. 831 831 )))
- 1735225942893-869.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.1 KB - Content
- 1739284154410-676.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.4 KB - Content