... ... @@ -59,8 +59,12 @@
59 59  
60 60  === Discharge current limit ===
61 61  
62 -TBA
62 +The BMS Main 3 device can check if the charging current exceeds the estimated limit based on the [[Discharge map>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HDischargemap"]].  If current exceeds the calculated limit more than configured difference, "Current limit" error is generated.
63 63  
64 +Current difference is configured by two regions separated by the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference.
65 +
66 +To change the overcurrent protection of the battery, select the "Protections → Charge current limit" section:
67 +
64 64  === Undervoltage ===
65 65  
66 66  The BMS Main 3 device implements battery protection from too low voltage on the cells.