Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -44,18 +44,8 @@ 44 44 45 45 === Charge current limit === 46 46 47 -T heBMS Main 3 device can check if the charging current exceeds the limit based on the Charge map. If current is more than estimated maximum, "Current limit" error is generated.47 +TBA 48 48 49 - 50 -To change the overcurrent protection of the battery, select the "Protections → Charge current limit" section: 51 - 52 -[[image:1735225207687-430.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="800"]]In this section: 53 - 54 -* Enable – a flag to enable the protection; 55 -* Threshold to switch from Region 1 to Region 2 56 -* 57 - 58 - 59 59 === Discharge current limit === 60 60 61 61 TBA ... ... @@ -407,7 +407,7 @@ 407 407 408 408 To change the protection parameters from short circuit, select the "Protections → Short circuit" section: 409 409 410 -[[image:1735224667621-969.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]]400 +[[image:1735224667621-969.png]] 411 411 412 412 In this section: 413 413 ... ... @@ -415,6 +415,8 @@ 415 415 ** Enable – a flag to enable the protection; 416 416 ** Maximum current, A; 417 417 ** Delay before setting the error, second; 408 +* Switch off the charging contactor on error – a flag to open the charging contactor when the "Short circuit" error occurs; 409 +* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Short circuit" error occurs; 418 418 * Delay before clearing the error, second; 419 419 * Lock – a flag to block the error until the device is restarted. 420 420 ... ... @@ -439,7 +439,7 @@ 439 439 440 440 To change the overheating protection parameters of power contactors, select the "Protections → High contactor temperature" section: 441 441 442 -[[image:173 5224706573-347.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]]434 +[[image:1733328415734-986.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 443 443 444 444 In this section: 445 445 ... ... @@ -448,6 +448,8 @@ 448 448 * Maximum contactor temperature, °C; 449 449 * Tolerant contactor temperature, °C; 450 450 * Delay before setting the error, second; 443 +* Switch off the charging contactor on error – a flag to open the charging contactor when the "High contactor temperature" error occurs; 444 +* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "High contactor temperature" error occurs; 451 451 * Delay before clearing the error, second; 452 452 * Lock – a flag to block the error until the device is restarted. 453 453 ... ... @@ -743,18 +743,14 @@ 743 743 744 744 To change the HVIL measurement parameters, select the "Protections → HVIL" section: 745 745 746 -[[image:173 5224839441-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]740 +[[image:1733328487099-371.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="800"]] 747 747 748 748 In this section: 749 749 750 750 * Enable – a flag to enable the protection; 751 -* Source is OFF: Lower current limit, A; 752 -* Source is OFF: Upper current limit, A; 753 -* Source is ON: Lower current limit, A; 754 -* Source is ON: Upper current limit, A; 755 755 * Lock – a flag to block the error until the device is restarted. 756 756 757 -If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored.747 +If interlock loop breaks, the “HVIL error” is generated. Error clears if interlock loop is being restored. 758 758 759 759 (% class="box warningmessage" %) 760 760 ((( ... ... @@ -810,7 +810,7 @@ 810 810 811 811 To change the general error parameters, select the "Protections → Critical error" section: 812 812 813 -[[image:173 5224942262-497.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]803 +[[image:1733328487101-216.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]] 814 814 815 815 In this section: 816 816 ... ... @@ -818,7 +818,7 @@ 818 818 * Delay before setting the error, millisecond; 819 819 * Delay before clearing the error, second; 820 820 * Lock – a flag to block the error until the device is restarted; 821 -* Errors 1, 2 to set the"Criticalerror"–bitfields to enable check of corresponding errors.811 +* Check: <error> – a flags to enable check of corresponding errors. 822 822 823 823 The general error flag is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time. 824 824
- 1735224839441-185.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.1 KB - Content
- 1735224942262-497.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.9 KB - Content
- 1735225207687-430.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.0 KB - Content